The VH1160 is compact, USB-based test hardware that automates conformance tests for CAN and LIN ECUs. It powers your ECU, switches terminals 15, 30 and 31′ independently and performs a hardware reset before each test case – all controlled directly from CANoe. Current measurement shows whether the ECU is in sleep or wakeup mode, and targeted short circuits and interruptions on the CAN and LIN lines let you run robustness tests automatically.
For high-performance ECUs with higher current demands, the VH1170 is the right choice.
Highlights
- Easy connection: Connect VH1160 to your computer via USB 2.0.
- Independently switchable terminals: Switch the power supply for automotive terminals ignition (IGN), VBatt and GND independently, with an LED showing the status immediately.
- Sleep/wakeup monitoring made easy: VH1160 measures the ECU's current consumption under program control to monitor sleep and wakeup states.
- Independent output voltage: Set the output voltage for terminals IGN and VBatt independently of the input voltage.
- Flexible power supply: Power VH1160 with either a standard desktop power supply or a lab power supply.
- Convenient control from CANoe: Operate VH1160 directly from CANoe.
Main Application Areas
Power Supply for Automated ECU Tests
- Every ECU test starts with powering the ECU, and a fixed supply such as a lab power supply often isn't enough. Some tests require switching terminals, setting over- or undervoltage conditions and possibly measuring current consumption at the same time. These tests can be time-critical and are no longer feasible manually.
That's exactly what VH1160 is built for: With its convenient connection to CANoe, it powers your ECUs in automated tests. It shows its strengths in LIN conformance tests and in the CANoe Test Package VAG, among others.
CAN and LIN Conformance Tests
- VH1160 is currently used by the CANoe Test Package VAG for CAN High-Speed and by the LIN conformance test implementation provided with CANoe Option LIN.
Gallery
Setup Overview


VH1160 Setup Overview
Functions
- Adjustable voltage from 2 V ... 28 V
- Individual control of terminals IGN, VBatt and GND
- Current measurement from 0 A ... 2.5 A
- Ground offset at the ECU and at the LIN line
- Limitation of the LIN line's recessive level
- Short circuits and interruptions on CAN and LIN lines
- Analog and digital I/O connections
Technical Data
| VH1160 | |
|---|---|
| External Power Supply | 12 V ... 24 V (±0.3 V accuracy), 5 A At 12 V ... 18 V, the VH1160 output current is reduced |
| Adjustable Output Voltage Terminal 15/30 (ECU Supply Voltage) | 2 V ... 28 V (±60 mV accuracy) Short-circuit proof Typical settling time ≤ 5 ms |
| Max. Output Current (ECU Current Consumption) | 2.5 A (input voltage ≥ 18 V) |
| Current Measurement | Measurement range 0 A ... 2.5 A Measurement location: supply line to the ECU Accuracy ±2 % or 0.5 mA |
| Relay for Terminals | Terminal 30, terminal 15, terminal 31' Typical switching time 7 ms |
| Temperature Range | 0 °C ... 50 °C |
| Dimensions (L × W × H) | 166 mm × 109 mm × 45 mm |
| Weight | 580 g |
Software Requirements
| Operating System | Windows 10, 11 |
|---|---|
| CANoe | Version 15 or higher |
| FTDI Driver | Version 2.08.30 or higher |
Product Descriptions and Downloads
FAQ
Related Products


Let's Discuss Your Use Case