VT2816 | VT2816 FPGA

General-Purpose Analog I/O Module

The module VT2816 provides 12 inputs and 4 outputs for analog signals. They may be connected directly to the inputs or outputs of an ECU. Also, other digital signals can be measured or controlled using this module, e.g. to control additional parts of a test bench. This module is also available as a variant (VT2816 FPGA) with user programmable FPGA.

General-Purpose Analog I/O Module: VT2816 | VT2618 FPGA

Characteristics:
VT2816

Functions for Each Channel

  • Voltage measurement with 2 measurement ranges
  • Differential or single-ended inputs (switchable)
  • Alternative current measurement with integrated shunt (eight channels)
  • Calculation of instantaneous, average, and effective values from the raw measurement values of the A/D converter; access to these values within CANoe

Functions for Each Output Channel

  • Voltage output with 2 switchable output ranges
  • Differential or single-ended output (switchable)
  • Autonomous output of a voltage curve loaded into module

Technical Data

VT2816
Voltage measurement
  Input Voltage (2 measurement ranges) -10 V … +10 V or -60 V … +60 V
  Input resistance Min. 1 MΩ
  Accuracy (at 25 °C)  
  – Measurement range ±10 V ± (1.5 % + 20 mV)
  – Measurement range ±60 V ± (1.5 % + 20 mV)
  – A/D converter (per channel, internal) 16 Bit / 250 kSamples/s
Current measurement
  Measurement range -5 A … +5 A
  Common mode voltage -60 V … +60 V
  Accuracy (at 25 °C) ± 50 mA
  A/D converter (per channel, internal) 16 Bit / 250 kSamples/s
Voltage output
  Output voltage (2 output ranges) -10 V … +10 V or 0 V … 28 V
  Output current Max. 200 mA
  Accuracy (at 25 °C)  
  – Output range ±10 V ± (0.3 % + 50 mV)
  – Output range 0 … 28 V ± (0.4 % + 28 mV)
  Slew rate (resistive load, 20 mA) Typ. 15 V/µs
  D/A converter (per channel) 14 Bit
Basic Data
  Supply voltage (via backplane) 12 V ±10%
  Power consumption Typ. 4.9 W
  Temperature range 0 … 55 °C
  Dimensions (L x W x H) 300 x 173 x 36 mm
  Weight Approx. 490 g
Maintenance
  Calibration recommended every 12 months
  Accredited (pre/re) calibration according to ISO/IEC 17025:2017

Schematic

Schematic of the channels of the VT2816

Related Products