CANape 17.0 SP7
Updates existing installations of version 17.0 to 17.0.70 SP7. The following changes become effective with version 17.0.70:
User Operation and Display
- Fixed a crash that occurred after hibernating/suspending PC when working with CANape and vCDMstudio
Communication Protocols
- Ethernet monitor: Stability improvement in case many signals are received via duplicated PDUs
Measurement Data Acquisition
- DHPR: "Working Directory" can be selected directly as MDF output path.
- Sporadic crashes during a measurement with DHPR devices have been fixed.
Calibration Data Management (Parameter sets & vCDMstudio)
- When creating a new dataset, the option "Separate A2L directory" is considered correctly. The respective file will be assigned to the new dataset.
- Fixed opening of the reference dataset in vCDMstudio. The column now is opened correctly when the window is activated.
- Improved robustness when inserting parameters into the CANape configuration: If dataset management is active and the current dataset does not contain all parameters, a check for this is done upon inserting.
Automation
- COM/API: The return value type of FifoLevel method has been corrected to Long.
- COM TCP: Fix the CANape startup in case of a 64Bit installation
VXplugin
- VX Tools: Integration of the latest version 4.2
Multimedia
- Improved video recording with pre-trigger time
Functions and Scripts
- Measurement functions support conversion rules defined for the function result.
- An issue that occurred when assigning a CASL function multiple times was solved.
Data Mining
- A sporadic problem at the start of data mining has been fixed.
Driver Assistance
- The display of the same multimedia signal in two Multimedia windows synchronized via the global measurement cursor also synchronizes the display of the GFX objects.
- CANape recognizes the license of the vSignalyzer Option Driver Assistance correctly again.
Working with Measurement Files
- The measurement file export converter into MATLAB format includes signal values marked with the invalid flag.
- The measurement export converter into ASCII format does not change dots inside string values into commas anymore.
- Displaying signals from MAT files will use the time channel of the signal group.
- Bus signal completion supports MF4 bus logging files containing floating point signals with a bit offset.
- Displaying string signals from TDMS files is supported now.
- The conversion of TDMS files correctly considers the properties.
- CANconv: Improved integrity check of PDU headers in dynamic container AUTOSAR PDUs
Category : | Service Pack |
Size : | 3.28 GB |
MD5 hash : | d6888ef238f71dc51f758e7961f4a736 |