CANape 15.0 SP5

Category: Service Pack
The download is not protected.
Size: Size: 1.51 GB
MD5 hash: 8a632b83a7f5d01c010161cfa986a81e

Updates existing installations of version 15.0 to 15.0.50 SP5.

The following changes become effective with version 15.0.50:

User Operation and Display

  • If a new signal is added to the measurement list via the measurement configuration and assigned to the default recorder, the link of that signal to the recorder is saved correctly in the CNA.

Communication Protocols

  • FlexRay: An error with bus synchronization for databases with missing communication parameters has been fixed.
  • XCP event list: If any required XCP command is not implemented, the automatic detection is suppressed.
  • Corrected an erroneous behavior: Devices can now be set to offline via the ribbon/quick access bar if a bus monitor has been removed from the device list before.
  • Added support for the CAN channels of ETAS ES592 hardware.
  • The MAX_ODT_ENTRY settings are now considered during XCP DAQ measurements.
  • XCP on CAN devices: The bus load regards the parameter MAX_BUS_LOAD from the ASAP2-database.
  • Added support of VX0312 for the bus analysis use-case.

Measurement Data Acquisition

  • The address extension of ECU symbols is stored in anonymous measurement configurations, too.
  • In case of splitting the measurement file during measurement, single CAN and Ethernet messages will be saved completely into the current file.
  • The option to repeat signal values measured on start of measurement in all split files of the measurement does work for large measurement files, too.

Database

  • The automatic detection of database changes has been improved.

Calibration Data Management (Parameter sets & CDM Studio)

  • When creating an empty PaCo file in vCDMstudio and entering data (by copying from other files and manually changing values), the curves and maps will always be saved according to the format specification. This will also be the case when the file is saved inbetween the individual changes.
  • When executing "Save as…" on a PAR file in vCDMStudio, the dialog to input a comment is displayed.
  • When a combo box is opened and active in the list window when vCDMStudio is closed, the transaction is finalized correctly before closing vCDMStudio.

Automation - COM/API

  • The functions Asap3GetMeasurementListEntries() and Asap3GetDatabaseObjects() now use the same syntax for object names.
  • The function Asap3GetEcuTasks2() now returns correct values in 64bit use-cases.
  • An error that occurred when a script should be run before measurement start has been fixed.
  • The recorder state is returned correctly when the recorder is preconfigured to start in pause mode.
  • Improved behaviour when calibrating objects with adress extension.
  • Improved behaviour in case of repeated attempts to start measurement of an offline device.

Extended MATLAB/Simulink Support

  • Improved search function for user-defined parameters in the Model Explorer.

Diagnostics

  • Diagnostic devices: The values of a table of variant-coded strings are displayed correctly again.

Bypassing

  • Improved handling of FlexRay signals for MATLAB/Simulink models running on VN89.

Data Mining

  • A problem that occured when processing video signals in Data Mining was solved.
  • Calling sub functions from functions is supported in Data Mining, too.

Measurement Data Visualization and Manual Analysis

  • Virtual algebraic signals can access other virtual signals, too.
  • "Display values from measurement file" supports device names with more then 31 characters.

Working with Measurement Files

  • The import of bus messages will show a warning if the description of a message is not contained in the database files.
  • The MATLAB export converter ignores unselected strings if signals are exported with a fixed time grid.
  • The measurement data export into MATLAB format ignores the configuration of a time grid when the option "Only one time channel" is used.


More about CANape...

Download now Previous