Converters for CANdela Diagnostic Descriptions for Windows 10, 8, 7, Vista, XP, 2000

Category: Add-On/Freeware
The download is not protected.
Size: Size: 74.69 MB
MD5 hash: f21b3bc304eb1846690f3081a5cdfa6a

CANdelaStudio and other Vector tools are delivered with the converters that are available when the tool is released. For loading newer versions of cdd-documents, you need the appropriate converter add-on. The add-on is delivered with a setup program which allows you to either install the converters for all Vector products installed on your system or to install the converters to a directory of your choice.

Issue:

CANdelaStudio or another Vector diagnostic tool fails to open a CANdela document (CDD file) because it does not support the document version.

Solution:

Please install the converter Add-on.

Background:

  • The file format of a newer CANdelaStudio version typically contains new diagnostic features (which Vector implements on customer request).
  • In a newer CANdelaStudio version, you can “Save As” to the file format of an older CANdelaStudio version. E.g. in CANdelaStudio 8.0, you can “Save As” to the CDD file format of CANdelaStudio 5.0.
  • As a default, other Vector diagnostic tools can open CANdela files in the format supported at the time of delivery, and older formats. E.g. CANoe 8.1 (without newer converters installed) can open CANdela files of CANdelaStudio 7.5.
  • But with a newer converter Add-on (also called “Persistors”), older CANdelaStudio versions and other Vector diagnostic tools can open even CANdela files saved with newer CANdelaStudio versions. It’s just the converter that must be new enough to support the new CANdela file format.
  • The converter is used by CANoe, CANalyzer, CANape, Indigo, CANdelaStudio, GENy (as part of CANdesc), vFlash, Canoe.DiVa, Test Automation Editor.
  • Vector diagnostic tools are delivered with the latest converter available at the time of delivery.
  • In the Vector diagnostic tools based on an older file format, the converter cannot make the new diagnostic features of the new file format available. It just provides a way to open the file and use the existing features of the program at hand. This is sufficient in most cases. If you need the new features, please purchase an upgrade of the Vector diagnostic tool.


Converter Installation Locations:

Up until 2012, each program installed had their own persistors installed locally in a subdirectory of the main program. This location usually was
\CANdelaStudio x.y\Bin\Persistors.
But with the variety of Vector tools using diagnostic capabilities, this resulted in a large amount of local installations, making inefficient use of disk space and sometimes in resulting of not all persistors being updated by the persistors’ setup program.
Starting in the 2nd half of 2012, new versions of Vector tools make use of one centralized persistors installation location which is C:\Program Files (x86)\Common Files\Vector CANdelaPersistors\Bin.
Since the 2nd half of 2013, the centralized persistors installation folder additionally contains a "Vector" subdirectory:
C:\Program Files (x86)\Common Files\Vector\CANdelaPersistors\Bin

Cannot open CANdela file even with Converters:

If the Vector diagnostic tool still cannot open a CANdela file of a different version, even after you installed the newest converter available, please try to copy the subdirectories of the above installation directory (see picture) to your respective …Persistors directory. This workaround should solve most issues. But be aware that you have to perform a complete installation first as these directories alone do not contain all persistors’ components. Some of the components are installed in the Windows directory.

Download now Previous