DaVinci Developer 3.0.37 SP1

Category : Service Pack
Size : 177.87 MB
MD5 hash : 55e2be0b628883a17c598fa95df0d38c

Contains the complete installation of DaVinci Developer 3.0.37 (SP1). For the operation a license of version 3.0 or higher is necessary. In case an according license is already activated on your PC no further renewal of this activation is necessary. For code generation, MICROSAR RTE 2.14 or 2.15 is required.

 

Detailed overview with the compatible MICROSAR RTE versions:

For configuring the MICROSAR basic software modules you need a compatible version of the DaVinci Developer or DaVinci Configurator Pro.

You may download the required version or service pack from DaVinci Service Packs Download.

Note:

With a license of the latest tool version you may also run any older version. You don’t need a separate older license.

DaVinci Developer compatibility

MICROSAR 4, Release 16 ff. (DaVinci Developer 4.x)

MICROSAR 4, Release 5-20 (DaVinci Developer 3.x)

MICROSAR 3, Release 13-19

MICROSAR 3, Release 8-12

MICROSAR 3, Release 3-7

DaVinci Configurator compatibility

 

MICROSAR 4

MICROSAR 3: use the latest version of DaVinci Configurator 4.2.x.

 

List of changes:

With Service Pack 1 (Update to 3.0 Build 37), the following changes become effective:

Tool features

  • Support of LIN Signal-Groups defined LDF files with the naming convention <signal_group_name>__<signal_name>
  • AliveTimeOut is now imported from DBC and can be propagated using a new function in the data mapping view
  • The newly introduced automatic ECU-C synchronization during workspace load/save can be switched off in the global settings dialog
  • Display of calibration objects in the graphic can be switched off in the workspace settings
  • Support of ARXML import pre-configuration using generic attribute IMPORT_MODE_PRESET
  • Constant property "Generate Symbol" can now be set in Library-Browser via multi-selection
  • Microsoft Windows 7 is now supported
  • New dialog for automatic connection of ports with enhanced matching algorithm and selection of desired connections in prior to apply the auto-connect
  • FlexNet license manager and Keyman dongle support has been updated to the latest version

Usability enhancements

  • DCF workspace performance has been improved when working on network drives of configuration management directories
  • DaVinci Difference Analyzer engine has been improved for 64bit windows systems
  • Workspace checker command line tool is now available to execute standalone consistency checks

Fixed issues

  • Wrong workspace conversion that causes missing Signal Group references during ECU-C synchronization has been fixed
  • Inconsistent connections (wrong sender/receiver direction) were not detected by a consistency check
  • Error message in the GUI when changing R-Port's "Handle Invalid" property has been fixed
  • Compatibility settings couldn't be set properly in the workspace settings dialog
  • DCF Utility didn't show Activation Offsets in the ECU-Project binary file
  • Missing check messages on inconsistent data mappings have been added
  • Additional name information for "DEFINITION-REF" objects in difference view have been added
  • Inconsistent structure of a complex constant compared to its data type have caused a generation error even if the constant was not actually generated.
  • Out-of-memory error message occurred in DCF Utility when opening large dcb files
  • Missing sorting of FIBEX-ELEMENT-REF in difference view has been fixed
  • Crash in DaVinci DEV has been fixed when switching to the ModeDelarationGroups in the properties view
  • Show in software design command for runnables in task mapping page didn't work.
  • Error Handling for ModeQueueLength '0' has been corrected
  • Within the data element prototype page the CreateNewDataType button didn't work
  • During ARXML import the renaming a child object didn't always work if the names only differ in character case
  • External tool command line parameters are changed back to default if no parameters are given in the dialog
  • The consistency check for Calibration Ports has been weaken to allow compatible interfaces that are not identical
  • ARXML import failed if existing objects only differ in character case from objects that were to be imported
  • Tool crashed when saving new SwBlockNeeds with a mirror PIM that had no data type
  • In read-only SWCs the implementation popup menus were not disabled and tool crashes if menu commands was executed
  • Tool slowed down after running several hours because of GUI resource leaks
  • Wrong setting of working folder in attached files dialog fixed that caused error message while opening generated attached SWC template file
  • Generated OSAlarm and OSEvents didn't match because the setting 'use shortnames > 32' was not consistently communicated to the RTE
  • Added multiple mapping of the same system signal on one frame to support the multiplexing use-case
  • Extended support for Tx/Rx split and signal overlay in the Multiple-ECU use-case
  • ARXML runnable import of Init-Trigger corrected if no other Trigger exists
  • Fixed error while synchronize structure of a complex constant in AUTOSAR export if the structure of the complex data type has been changed
  • Newly created graphic sheet names were not stored correctly in the workspace
  • ECU-C file data wasn't fully loaded during opening DCF workspace if the AUTOSAR schema versions have been different
  • Generic attribute definitions weren't loaded during opening DCF workspace if a corresponding generic attribute didn't exists at an AUTOSAR object
  • Missing error message while opening incompatible workspace with RTE Generator fixed
  • Generation of templates and contract headers is now allowed for service components
  • Sorting of error/warning/info icons in the messages tab has been corrected
  • The initial graphic scroll-bar position was often not correct
  • Newly created Port-Prototypes are now automatically positioned near the original port
  • Auto-mapping for wasn't working well with multi instance SWC
  • Directory placeholders with workspace variables were not working correctly for DCF workspaces
  • Service mapping was missing when exporting service layer components to ARXML or DCF
  • Property dialog for NvM block needs threw an error when using read-only Component-Types
  • Some issues in workspace merger functionality have been fixed concerning communication merge, generic attributes, and data-mapping
  • The global attribute definition file in a DCF workspace can now be modified in the DCF-file to share it among DCF workspaces
  • The Mode disabling dependencies for runnable triggers were doubled during the XML import
  • Task attributes priority / description / schedule were incorrectly loaded from DCF workspaces
  • Signal bit length was not updated from DBC file if the signal with data-type reverence already exists
  • Service needs were deleted during special diagnostic import
  • Bad performance while switching from structure design to port prototype view solved by specifying the list view as default editor for non-graphic use-cases
  • ECU-C synchronize of Init Values produced unnecessary warning output
  • Init value check for the Data Mapping didn't work
  • Incorrect Exclusive Area Access after DCF loading if AR 2.1 SWC are used together with AR 3.0 ECU-C file
  • Attribute definition inconsistencies weren't reported during DCF loading
  • Inconsistent NvM block and PDAV order was not reported by a check
  • Signal's unit was not imported via LDF file
  • Crash has been fixed while opening ECU Project Software Design editor after large SWC was updated by importing new SWC definition
  • Loading of global generic attribute definitions has been restructured to avoid overwriting with local attribute definition during DCF loading
  • Wrong consistency message concerning maximum values was displayed due to rounding problems in physical value calculation
  • Workspace settings were reset on saving a DCF workspace as DEV
  • Read-only ECU-Projects were missing after loading a DEV workspace which was created out of an DCF workspace
  • Crash during DCF save has been fixed if many read-only DCF files are about to be stored
  • Signal length was set to null after a LDF file has been updated through the ECU-Project signal list
  • Data mapping was missing after loading DCF workspace if atomic software components were multiply instantiated within an ECU-Project
  • Update icon was not correctly displayed in Attached-Files dialog
  • In rare cases DCF save aborted with COM Error 0x80070057 if the ECU-Project contains a large amount of Software Component Prototypes
  • A wrong ECU-C file with invalid container definitions crashed the DCF workspace loading
  • USB dongle access caused GUI freeze in some situations
  • Workspace checker command line tool threw a Rte Generator error message if the standard generator wasn't defined
  • COM-Error code 0xC0500012 was thrown on importing ARXML if software component types already existed in the workspace but have been deleted manually in prior to import

Download now Previous