VT7101
Power Supply Module
Characteristics:
VT7101
Module Features
- 2 external power supplies can be connected
- Internal power supply generates voltage for the ECU from the VT System power supply
- 2 external and 1 internal power supplies may be connected to the 2 outputs to the ECU in various combinations
- Ground lines of outputs can be interrupted (line break of terminal 31)
- Relays for producing short circuits between the output lines
- Measurement of output currents over a very wide range
- Measurement of input and output voltages
- Control of two external power supplies via control voltage or via electrically decoupled serial interfaces
- Generation of arbitrary control voltage curve
- Serial interface for driving an external display
- Hardware synchronization with Vector network interfaces
- The module supplies ground and battery voltage to the bus bars at additional pins
Technical Data
VT7101 | ||
Input voltage | -60 … +60 V | |
Current carrying capacity (at 0 … 35 °C) | ||
One channel | Max. 70 A | |
Both channels in sum | Max. 100 A | |
Internal power supply | ||
Output voltage | 3 … 59 V | |
Accuracy (at 25 °C, 0.5 A) | ± (0.5 % + 100 mV) | |
Max output | ||
– Current | 2 A | |
– Power | 30 W | |
Current measurement | ||
Measurement ranges | 7 (100 µA … 100 A) | |
Accuracy (at 25 °C) | ± (0.1 % + offset) (offset is dependent on measurement range) | |
A/D converter (per channel, internal) | 16 Bit / 250 kSamples/s | |
Voltage measurement | ||
Accuracy (at 25 °C) | ± (0.5 % + 25 mV) | |
A/D converter (per channel, internal) | 16 Bit/250 kSamples/s | |
Control voltage of external power supply | ||
Control voltage for voltage/current | -10 … +10 V | |
Accuracy (at 25 °C) | ± (0.01 % + 10 mV) | |
Output current | Max. 30 mA | |
Basic Data | ||
Supply voltage (via backplane) | 12 V ±10 % | |
Power consumption (all relays off) | Typ. 7 W | |
Power consumption (8 relays active, output 12 V/1 A via internal power supply | Typ. 33 W | |
Temperature range | 0 … 55 °C | |
Dimensions (L x W x H) | 300 x 173 x 36 mm | |
Weight | Approx. 1,240 g | |
Maintenance | ||
Calibration recommended | every 12 months | |
Accredited (pre/re) calibration according to | ISO/IEC 17025:2017 |