VT2808
Characteristics:
VT2808
Functions for Each Channel
- Current measurement with 3 measurement ranges (automatic range switching)
- Simultaneous voltage measurement
- Measurement related to external reference or ground (switchable)
- Alternatively, current measurement with an external measuring resistor
- Calculation of instantaneous, maximum, and minimum values from the raw measurement values of the A/D converter; access to these values within CANoe
Technical Data
VT2808 | ||
Voltage Measurement | ||
Input voltage | -60 V … +60 V | |
Accuracy (at 25 °C) | ± (0 % + 50 mV) | |
A/D converter (per channel, internal) | 16 Bit / 250 kSamples/s | |
Current Measurement | ||
Measurement range | ≤ 50 mA; ≤ 1 A; ≤ 16 A (automatic switching) | |
Accuracy (at 25 °C) | ||
– Measurement range: ≤ 50 mA | ± (0% + 0.1 mA) | |
– Measurement range: ≤ 1 A | ± (0% + 10 mA | |
– Measurement range: ≤ 16 A | ± (0% + 100 mA | |
A/D converter (per channel, internal) | 16 Bit / 250 kSamples/s | |
Basic Data | ||
Supply voltage (via backplane) | 12 V ±10% | |
Power consumption | Typ. 6.1 W | |
Temperature range | 0 … 55 °C | |
Dimensions (L x W x H) | 300 x 173 x 36 mm | |
Weight | Approx. 432 g | |
Maintenance | ||
Calibration recommended | every 12 months | |
Accredited (pre/re) calibration according to | ISO/IEC 17025:2017 |