Issues solved

  • Multiple CAN protocol messages are always processed with a delay of 1ms (PTH-41437)
    The PassThru CAN protocol channel implementation had a less performant algorithm when multiple CAN protocol messages were sent (e.g. application ISO15765 implementation).
  • Byte alignment size for 64-bit PassThru XL Library is not set to one (1) (PTH-41439)
    For 64-bit PassThru XL Library, the byte alignment wasn't set to one (1) byte as specified within J2534-1, section 9.2.2.
Please note:
This software package contains an older version of WIBU CodeMeter, which contains a critical security vulnerability.
Please ensure to have the latest Vector License Client installed that fixes that vulnerability. For details refer to the Vector security advisory.