GL Logger
The GL Logger Family for Automotive, Commercial Vehicles and Avionic

Data Logging with the GL Logger Family

The GL Loggers are special automotive data recorders which can be used in test vehicles or on test benches. They record measurement values and acquire the data communications of CAN/CAN FD, LIN, FlexRay and MOST150 bus systems.

Beside bus communication you can store in addition internal ECU parameters via CCP/XCP and diagnostics as well as measured values of digital and analog inputs in a time-synchronous manner.

Advantages

  • Flexible loggers for test fleet operators and individual testing tasks
  • Permanent use in automotive and commercial vehicles due to low current consumption in Sleep/Standby mode
  • Robust equipment for summer and winter trials
  • Reliable during long-duration recordings
  • Event-driven recording for data reduction
  • Supports the early quality assurance of the later mass production
  • Special avionic logger for flight tests

Application Areas

Whether you are busy in automotive, commercial, avionic or transportation industry the GL Loggers support these application areas:

  • Use in test fleets as well as in single vehicles
  • Flight test equipment
  • Long-term recording
  • Customized test tasks
  • Summer and winter vehicle trials
  • Quality assurance

Highlights of All GL Loggers

  • Stand-alone tools for challenging logging tasks
  • Very short start-up times
  • Extensive filter and trigger conditions
  • Support of diagnostics and CCP/XCP
  • Compact data storage on SD/CF cards or SSD with high memory capacities
  • Quick data read-out
  • Graphical configuration tool makes it easy to configure
  • Offline analysis with the familiar Vector software tools CANoe, CANalyzer, CANape and vSignalyzer

General Functions

Main Logging Features of the GL Loggers

  • Time-synchronous logging of these bus systems:

    • CAN: with loggers of the GL1000/GL2000/GL3000/GL4000/GL5000 families
    • CAN FD: with GL2400 and GL5000 family
    • LIN: with loggers of the GL1000/GL2000/GL3000/GL4000/GL5000 families
    • FlexRay: with loggers of the GL4000/GL5000 families
    • MOST150: as an option with loggers of the GL3000/GL4000/GL5000 families

  • Very short start-up times
  • The system start is acquired from Standby mode (GL2000/GL3000/GL4000 families)
  • Very low current consumption in Sleep and Standby modes for continuous duty in test fleets
  • Extensive filter conditions to reduce data volume
  • Complex trigger conditions for triggering on messages, signals, inputs, manual button activation
  • Import of databases DBC (CAN), LDF (LIN), FIBEX (FlexRay) and ARXML (AUTOSAR format for CAN, FlexRay)
  • Possible to send CAN messages
  • Timeout monitoring for messages
  • Online classing
  • Battery-buffered real-time clock for logging date and clock time

 

Afficher plus

Diagnostics:

  • Time-synchronous recording of diagnostic data
  • Protocols: UDS, KWP2000 on CAN and OBD II
  • Sending diagnostic requests at configurable events (start, CAN ID, signals, keys, digital inputs, etc.)
  • Parameterization via the diagnostic descriptions of CDD, ODX, PDX, MDX

 

CCP/XCP:

  • Cyclic time-synchronous recording of CCP/XCP measurement data in DAQ and polling mode
  • Support of CCP V2. 1, XCP on CAN V1.x
  • Support of XCP on FlexRay (GL4000/GL5000 family only)
  • Support of Seed & Key for the above mentioned protocols
  • For implementing seed & key CANape is required
  • Record internal ECU data with VX module and serial POD without load on vehicle buses. XCP on Ethernet (DAQ mode) allows for a much higher data rate than XCP on vehicle buses. (GL3000/GL4000/GL5000 family only)
Afficher plus
  • Time-synchronous logging of measured values of analog inputs and the states of digital inputs in addition to logging bus communications
  • Signal tone can be output for events using the configurable buzzer
  • Status indicator with LEDs on the logger or on the remote control device
  • Status indicated on display (only for GL3100/GL3200/GL4000/GL4200/GL5000)
  • Pushbuttons on loggers and on remote control device for manually initiating a trigger
Afficher plus
Overview of Used Storage Media
  • Compact storage of the logged data on quickly removable storage media
  • High capacity storage media
  • GL1000/GL2000 family: SD/SDHC memory card
  • GL3000/GL4000 family: CF memory card, Solid State Disc and USB storage media
  • GL5000 family: Solid State Disc
Afficher plus
Data Transfer and Export of Logged Data

  • Fast read-out of the data directly via USB of the loggers, via SSD or via SD/CF card in commercially available card readers
     
  • GL2000/GL3000/GL4000/GL5000 family: wireless data transmission for automated upload of logged data and update of a new logger configuration:

    • via WLAN/WiFi: for GL3000/GL4000/GL5000 family
    • via 3G/UMTS: for GL2000/GL3000/GL4000/GL5000 family
       

  • Automatic conversion of the logged data depending of the bus system in the following formats:

    • Message-oriented: BLF, ASC, ADTF, IMG and TXT
    • Signal oriented: MDF, MATLAB© v7.3, HDF5 and TXT
    • Raw data: CLF

Afficher plus
Monitoring of the Vehicle Buses with CANoe/CANalyzer
  • GL2000/GL3000/GL4000 family are monitoring interfaces for the monitoring of bus communication with CANoe or CANalyzer
  • Easy connection of PCs with CANoe or CANalyzer with the loggers via Ethernet
  • Use the existing logger connections to the vehicle buses
  • License for the bus systems in CANoe or CANalyzer required
Afficher plus
Offline Analysis with Vector Tools and 3rd Party Tools
  • Analysis of the recorded data with known functions of Vector software tools CANape, CANoe, CANalyzer and vSignalyzer and with Microsoft Excel
  • The above mentioned Vector tools support the direct import of the raw format CLF
     
Logging
Format
CANoe,
CANalyzer
CANape,
vSignalyzer
3rd  Party
Tools
Signal
Oriented
Message
Oriented
Note
ASC yes yes yes - yes ASCII
(for Vector tools)
BLF yes yes - - yes Binary
MDF yes yes yes yes - Binary
IMG yes - - - - Only MOST data
MAT - - yes yes - MATLAB© V7.3
(for 3rd party tools)
HDF5 - - yes yes - H5, HE5, HDF5
(for 3rd party tools)
ADTF - - yes - yes
For 3rd party tools
TXT - - yes yes yes
Text format
(e.g. for MS Excel)
CLF yes yes - - yes Raw format of the GL Loggers
Afficher plus

Special Functions

Diagnostic Functions of the GL Loggers

The loggers of the GL family have a comfortable diagnostic interface and thus allow a more comprehensive collection of vehicle data. The diagnostic data are cyclical or event-driven read out from the ECU of vehicle and time synchronized with all other logging data recorded.

The parameterization of the diagnostic request is as simple as symbolic choice of CDD, PDX and ODX and MDX files with the help of the 'Vector Logger Configurator'. The loggers support the common diagnostic protocols UDS, KWP2000 and OBD II.


An example - CAN diagnostics workflow:

Afficher plus
Logging of ECU Parameters over CCP/XCP

The CCP/XCP logger option lets you time-synchronously log internal ECU parameters via cyclic DAQ lists or the polling mode. After an unexpected disconnection the GL loggers automatically restart the CCP/XCP connection.

A CCP/XCP license must be installed on the logger. The license includes depending on the logger CCP/XCP on CAN, XCP on FlexRay and for the VX modules XCP on Ethernet.

 

Supported protocols are:

Protocol
Loggers
DAQ
Polling
Seed & Key
CCP/XCP on CAN    
All GL loggers
yes
yes
yes
XCP on FlexRay    
GL4000/GL5000 family only
yes
-
yes
XCP on Ethernet    
GL3000/GL4000/GL5000 family only for recording via Vector VX modules with serial POD and CSM EtherCAT XCP Gateway 
yes
-
-


To implement Seed & Key CANape 8.0 or higher is required.

 

 

The CCP/XCP logger option for time-synchronously logging internal ECU parameters via cyclic DAQ lists or the polling mode
Afficher plus
Logging MOST150 Data from Multimedia Devices
Logging accessory GLA150 supports time-synchronous recording of MOST150 data

The GLA150 is the first MOST150 logger interface that is listed by the MOST Cooperation as MOST compliant.
 

Time-synchronous recording of MOST150 data can be done with the loggers of the GL3000/GL4000/GL5000 families and the GLA150 accessory. The GLA150 enables the very fast data transfer rate for MOST.

The GLA150 is based on the proven Vector MOST150 interface VN2640 for CANoe and CANalyzer. Only with the support of GLA150, the loggers record the control channel and the asynchronous channel with MOST data packets (MDP) as well as with MOST Ethernet packets (MEP). The subsequent evaluation is done with the extensive functions of CANoe or CANalyzer.

Afficher plus
Inputs and Outputs for Further Measurement Tasks and to Control External Hardware

All GL loggers have multiple analog inputs as well as digital inputs and outputs. For loggers of the GL3000/GL4000/GL5000 families, it is possible to increase the number of analog inputs by means of an expansion board.

You can use the analog and digital inputs of GL loggers to log measurement values of external modules time-synchronously to the bus communication. The digital outputs can be used to control external modules, e.g. to turn them on or off.

 

Afficher plus
GL2000/GL3000/GL4000/GL5000 families - Wireless data transmission over WLAN or 3G/UMTS

The Wireless LAN and 3G/UMTS logger options are available for wireless transmission of logging data from vehicles to a server as follows:

  • GL2000 family: Option 3G/UMTS
  • GL3000/GL4000/GL5000 families: Option WLAN and 3G/UMTS

To reduce the volume of data, you may transmit just a subset of the data. The loggers initiate the connection to your server. The trigger condition for initiating a connection is configurable.

The ML Server Software saves the logged data in a separate structure for each logger and then automatically converts it to the desired data format (e.g. BLF, ASC, MDF). If necessary, this software can upload a new configuration from your server to the GL loggers. The loggers update this configuration after a restart.

Afficher plus

GL Logger Family in Detail

Afficher plus

GL1000 / GL1010

GL1000, GL1010 – Compact data loggers for CAN, LIN, I/O in standard design and IP65 design

GL1000
The optimal solution for operators of test fleets for logging the CAN and LIN data communication of small networks. Messages are saved and evaluated according to the loaded configuration. In addition, its very compact package simplifies installation of the logger in any vehicle.

GL1010
The IP65 variant for use in rough surroundings on test drives.

 

Functions:

  • Simultaneous logging of 2 CAN channels (e.g. 100 % bus load at 500 kBit/s), 2 LIN channels and 4 analog and 2 digital inputs
  • Saving of data on SD card (up to 2 GB) resp. SDHC card (up to 32 GB)
  • Fast start-up time, typical 150 ms
  • Permits continuous use in vehicle due to low current consumption in Sleep mode
  • Fast read-out of the logging data directly via USB, commercially available SD/SDHC card reader
  • Automatic conversion to BLF, ASC, MDF or TXT format
  • Ring buffer, e.g. for long-term or event-driven logging
  • Logging of diagnostic data over CAN
  • Optional measurement data acquisition over CCP/XCP as well, including with seed & key
  • Signal sound by buzzer
  • GL1010 as IP65 variant
  • Easy-to-use graphical configuration tool

 

Afficher plus

GL2000 / GL2010 / GL2400

GL2000, GL2010 - Handy data loggers for CAN, LIN, I/O, 3G/UMTS in standard design and IP65 design

GL2000

This logger is the ideal solution for operators of test fleets to log the CAN and LIN data communication of moderate-sized networks. Messages are saved and evaluated according to the loaded configuration. This logger exhibit low current consumption in Sleep mode and are therefore ideal for continuous use in the vehicle. The GL2000 is immediately ready to log from Standby mode, so the system start can be acquired. In addition, its compact package simplifies installation of the logger in any vehicle.

GL2010 is the IP65 variant for use in rough sourroundings on test drives.

GL2400 adds the CAN FD support to the GL2000 feature set.

Functions:

  • Simultaneous logging of 4 CAN channels, 2 LIN channels and 4 analog and 4 digital inputs
  • GL2400 supports 4 CAN/CAN FD channels
  • Saving of data on SD card (up to 2 GB) resp. on SDHC card (up to 32 GB)
  • Fast start-up time, typical 170-180 ms - provided: 2 GB Xmore SD memory card
  • Recording of the system startup (wake-up cause) from standby mode (GL2000, GL2010 only)
  • Permits continuous use in vehicle due to low current consumption in Sleep mode (<1 mA) or in Standby mode (typ. 60 mA)
  • Logging of the system start (case of wake-up) from Standby mode
  • Fast read-out of the logging data directly via USB orcommercially available SH/SDHC card reader
  • Optional wireless data transmission via wireless 3G/UMTS to upload the logged data and to download a new configuration
  • Automatic conversion to BLF, ASC, MDF or TXT format
  • One ring buffer either for long-term or for event-driven logging
  • Supports databases for symbolic selection of messages and signals in configuring filter and trigger conditions
  • Remote controlled initiation of a manual trigger
  • Logging of diagnostic data over CAN, import of diagnostic descriptions in CDD, ODX/PDX and MDX formats
  • Optional measurement data acquisition over CCP/XCP as well, including with Seed & Key
  • Online classing
  • Signal sound by a buzzer
  • GL2010 as IP65 variant
  • Easy-to-use graphical configuration tool

 

Further infos in our video "Logging and Data Analysis with GL2000" ( English subtitles, 3:50 min):

Video about logging and data analysis with the data logger GL2000 (with English subtitles)
Afficher plus

GL3000 / GL3100 / GL3200 / GL4000 / GL4200

The loggers of the GL3000 family are the perfect solutions for operators of test fleets who need to record extensive CAN/LIN networks or the optional MOST150. These loggers exhibit low current consumption in Sleep Mode and are therefore ideally suited for continuous use in the vehicle. The loggers are immediately ready for operation from Standby mode, so that the system start can also be acquired.

The loggers of the GL4000 family offer all of the functionality of the GL3000 family and also offer access to FlexRay.


Functions:

  • Simultaneous logging of 9 CAN channels, 2 LIN channels and 14 analog and 8 digital inputs
  • GL4000 family: additional 2 FlexRay channels
  • Saving of data on CF card (GL3000, GL3100, GL4000) or SSD (GL3200, GL4200)
  • Fast start-up time, typical 20 ms
  • Permits continuous use in vehicle due to low current consumption in Sleep mode or Standby mode
  • Logging of the system start (case of wake-up) from Standby mode
  • Fast read-out of the logging data directly via USB, commercially available CF card reader or Ethernet
  • Optional wireless data transmission via wireless LAN or 3G/UMTS to upload the logged data and to download a new configuration
  • Automatic conversion to BLF, ASC, MDF, IMG or TXT format
  • 2 independently configurable ring buffers, e.g. for long-term or event-driven logging
  • Extensive filter and trigger conditions
  • Supports databases for symbolic selection of messages and signals in configuring filter and trigger conditions
  • Remote controlled initiation of a manual trigger
  • Logging of diagnostic data over CAN, import of diagnostic descriptions in CDD, ODX/PDX and MDX formats
  • Optional measurement data acquisition over CCP/XCP as well, including with Seed & Key
  • Optional extension for MOST150 via the GLA150 module
  • Online classing
  • Logger as alternative interface hardware for monitoring applications in CANoe or CANalyzer
  • Easy-to-use graphical configuration tool
Afficher plus

GL5350 / GL5370

GL5350 - Multibus data logger with CAN FD

The GL5350 is the perfect solution for operators of test fleets who need to record extensive CAN/CAN FD/LIN/FlexRay networks or optional MOST150. With its powerful hardware it supports you in complex logging tasks. The logger exhibits low current consumption in sleep mode and is therefore ideally suited for continuous use in the vehicle.

GL5370 offers more CAN channels and significantly more CAN FD channels with the same range of functions.

 

Functions:

  • Simultaneous logging of up to 24 CAN channels, 6 LIN channels, 2 FlexRay channels, 1 MOST150 channel,  14 analog and 4 digital inputs

    • GL5350: 20 CAN channels, thereof 4 CAN FD channels
    • GL5370: 24 CAN channels, thereof 12 CAN FD channels

  • CAN FD channels selectively configurable for ISO CAN FD or NON-ISO CAN FD  
  • Saving of data on SSD with high-capacity
  • Fast start-up time, max. 40 ms
  • Permits continuous use in vehicle due to low current consumption in sleep mode
  • High performance for demanding tasks
  • Fast read-out of the logging data directly from SSD or via USB
  • Optional wireless data transmission via wireless LAN or 3G/UMTS to upload the logged data and to download a new configuration
  • Independently configurable ring buffers, e.g. for long-term or event-driven logging
  • Extensive filter and trigger conditions
  • Supports databases for symbolic selection of messages and signals in configuring filter and trigger conditions
  • Remote controlled initiation of a manual trigger
  • Logging of diagnostic data over CAN via UDS, KWP2000 on CAN and OBD II. Import of diagnostic descriptions in CDD, ODX/PDX and MDX formats
  • Optional measurement data acquisition over CCP/XCP as well, including with Seed & Key
  • Optional extension for MOST150 via the GLA150 module
  • Automatic conversion to BLF, ASC, MDF, IMG or TXT format
  • Online classing
  • Easy-to-use graphical configuration tool
Afficher plus

GL1020FTE - Flight Test Equipment for Avionic Industry

Avionic logger GL1020FTE - Special flight test equipment to record avionic CAN bus communication

The data logger GL1020FTE is a flight test equipment to record avionic bus communication. It is designed for application in the pressurized fuselage area to independently record communication data of various aircraft systems during flight testing.
The logger meets the typical avionic requirements on electromagnetic compatibility (EMI).

 

Avionic Features:

  • Designed for compliance with DO-160E
  • No impact on the bus communication in the aircraft
  • Protection from short circuit
  • Protection from indirect lightning effects
  • Mounting plate with bonding point
  • RF emission and susceptibility according to typical avionic requirements
  • Operational at altitudes up to 36,000 ft
  • Housing in RAL2004 color
Afficher plus

Poster

Vector offers specialized logging solutions for in-vehicle use on test drives or for test benches.
 

This reference chart gives you:

  • An overview about the Vector logging solutions
  • Illustrates the logging process
  • Indicates the configuration possibilities


Format: DIN A1 upright, folded to DIN A4

Comparison of the GL Loggers

GL1000
GL1010 (IP65 variant) 
GL2000
GL2010 (IP65 variant)
GL2400 
GL3000
GL3100
GL3200
GL4000
GL4200
GL5350
GL5370
Bus systems logging
CAN, LIN CAN, CAN FD, LIN CAN, LIN, MOST150 CAN, LIN, FlexRay, MOST150
CAN, CAN FD, LIN, FlexRay, MOST150
Channels
2 x CAN
2...12 x LIN
4 x CAN
2...12 x LIN
GL2400:
4 x CAN FD
9 x CAN
2..1.6 x LIN
1 x MOST150
9 x CAN
2..16 x LIN
2 x FlexRay
1 x MOST150
GL5350:
20 x CAN, incl. 4 x CAN FD
GL5370:
24 x CAN, incl. 12 x CAN FD

6...16 x LIN
2 x FlexRay
1 x MOST150
Memory
Max. 32 GB
(SD/SDHC card)
Max. 32 GB
(SD/SDHC card)
GL3000/GL3100:
Compact flash cards (no limit), USB memory media
GL3200:
512 GB SSD
GL4000:
Compact flash cards (no limit), USB memory media
GL4200:
512 GB SSD
512 GB SSD
Data transfer
USB USB, UMTS USB, Ethernet, Wi-Fi, UMTS USB, Ethernet, Wi-Fi, UMTS
USB, Wi-Fi, UMTS
Wake-up, Sleep mode functionality
Yes Yes Yes Yes
Yes
Start-up time
typ. 150 ms
(with 2 GB Xmore SD card)
typ. 170 ms
(with specified Xmore SD card)
Max. 20 ms
Longer start-up time with MOST150
Max. 20 ms
Longer start-up time with MOST150
Max. 40 ms
Longer start-up time with MOST150
Control inputs/outputs
2 digital inputs/outputs
(0 V...36 V)

4 analog inputs
(0 V...16V)
4 digital input/outputs
(0 V...36 V)

4 analog inputs
(0 V...18 V)
Max. 20 ms
Longer start-up time with MOST150
Max. 20 ms
Longer start-up time with MOST150
4 digital inputs/outputs each
6 analog inputs (0 V...32V)

Optional: Board with
8 analog inputs (0 V...18V)
Keyboard/display
No No GL3100/GL3200:
4 keys, 1 display
4 keys, 1 display
4 keys, 1 display
Supply voltage
5 V...30 V 6 V...30 V 6 V...36 V 6 V...36 V
7 V...50 V
Temperature range
GL1000:
-40 °C...+ 85 °C
GL1010:
-20 °C...+ 80 °C
(depending on SD card)
GL2000/GL2400:
-40 °C...+ 80 °C
GL2010:
-20 °C...+ 80 °C
Operating: -40 °C...+70 °C
Operating: -40 °C...+70 °C
Operating: -40 °C...+70 °C
Dimensions (approx. L x H x D)
GL1000:
107 x 85 x 35 mm
GL1010:
130 x 85 x 35 mm
GL2000/GL2400:
194 x 137 x 35 mm
GL2010:
175 x 137 x 35 mm
213 x 78 x 235 mm
213 x 78 x 235 mm
290 x 74 x 212 mm 

 

Configuration Programs

The Vector Logger Configurator is the comfortable program for creating configurations for all loggers of the GL families. The program is already included in the scope of delivery.

The Vector Logger Configurator is used to configure hardware settings for the CAN, CAN FD, LIN, FlexRay and MOST150 channels. This includes configuration of the filter and trigger conditions, logging of analog and digital inputs. CCP/XCP measurements and diagnostic requests for reading out internal ECU data are also configured with this program. LEDs can be set to indicate individual events. The Vector Logger Configurator supports reading out the logged data and converting it to a variety of logging formats for the various target groups. In addition, the logging files can be easily exported from archived raw data (ZIP format) to other formats or with additional options – even later on.

Afficher plus

The new Vector Logging Exporter is a separate program for readout stations that enables convenient and intuitive conversion of the logged data of all Vector loggers in the necessary target formats for the various target groups. The program is included in the scope of delivery.

The Vector Logging Exporter automatically determines the logger type and the associated analysis package from the logging files. The data is selectively read from the connected logger, card reader, or a directory on a hard disk or server. You can quickly select the export settings for each target group using preset conversion profiles. With the Vector Logging Exporter, you thus provide the logged data promptly in the desired target formats to all target groups. In addition, the logging files can be easily exported from archived raw data (ZIP format) to other formats or with additional options – even later on.

Afficher plus

Accessories

Extension board for wireless data transfer via Wi-Fi

For the GL3000/GL4000 family the WiFi board is used for the wireless transfer of logging data files from vehicles that are parked at stationary locations. Additionally you can update the configuration and firmware of the logger via WiFi. For the data transfer the ML Server software must be installed on the PC.


Highlights:

  • Particularly suitable for use in test fleets due to automatic data transfer
  • Transfer only selected logged data is configurable
  • Connection to several serves in different locations possible
  • Data transfer via WiFi according to IEEE 802.11b/g (54 Mbit/s)
  • Encryption via WPA, WPA2
  • Security protocols EAP/TLS, TKIP, RADIUS
Afficher plus
Modem for wireless data transfer via 3G/UMTS

For the GL3000/GL4000 family the compact 3G modem GLA320 is used for the wireless transfer of logging data files from vehicles independent from their position. Additionally you can update the configuration and firmware of the logger via 3G. For the data transfer the ML Server software must be installed on the PC.
For the GL2000 family an alternative 3G module is available.


Highlights:

  • 3G support with fallback to GSM/GPRS/EDGE
  • Transfer only selected logged data is configurable
  • Use in test fleets in different European countries (EU), North America, Japan, Malaysia
  • Roaming is adjustable
  • Quickly changeable SIM cards (not included in delivery) for cross-border test drives
Afficher plus
Logging of vehicle position via GPS

Use this GPS receiver to also record the position of your vehicle time-synchronously to the bus communication.

For the GL2000 family an alternative GPS module is available.

 

Highlights:

  • 12 channel GPS receiver
  • Receiving frequency: 1575.42 MHz, L1 band
  • Measurement values updated with frequency of 1 Hz or 5 Hz
  • Data output over RS232 in NMEA0183 format and/or to CAN
  • For CAN, the cycle time and identifier are configurable
Afficher plus
Voice recorder to log user ­comments & voice ­output on specific events

With loggers of the GL2000/GL3000/GL4000/GL5000 family, you can use VoCAN to add comments to events during logging with a voice recording in audio format. The loggers of the GL3000/GL4000/GL5000 family also allow output voice messages, such as general information or instructions for the driver.


Highlights:

  • Voice recording by directional microphone, date and clock time in the file name
  • Voice output
  • Sound output
  • 4 user-programmable colored LEDs
  • 1 user-programmable pushbutton
  • High-speed CAN interface
Afficher plus
Logging of user comments on specfic events

Use CASM2T3L in combination with the loggers of the GL2000/GL3000/GL4000/GL5000 family to add comments to events during logging with a voice recording in audio format.

 

Highlights:

  • Voice recording, date and clock time in the file name
  • Sound output
  • 3 user-programmable colored LEDs
  • 2 user-programmable pushbuttons
  • High-speed CAN interface
  • Suitable for vehicle cup holders
Afficher plus
Digital camera for high-quality color photos

This compact, digital network camera gives you the ability to supplement your logged data with high-quality color images for GL3000/GL4000/GL5000 loggers. The environmental during a test drive or of vehicle components is thus documented graphically.   

 

Highlights:

  • Records images or image sequences with date and clock time in file name
  • JPEG image format with configurable compression
  • Time-synchronous logging
  • Image rate up to 25 images/s
  • Resolution 1280 x 720  to 320 x 180 pixels
  • Configurable shutter speed
  • Transfer of images from the ring buffer to the logger periodically or on event
Afficher plus
External extension for up to 14 LIN channels

External LINprobe adapters are available for all GL loggers to log additional LIN channels. You can send LIN frames, too.

 

Highlights:

  • LIN extension with 2 LIN channels with the following variants:

    • LINprobe R receives LIN frames
    • LINprobe X receives and sends LIN frames. When sending, LINprobe X serves as either Master or Slave.
    • LINprobe G receives and sends LIN frames, like LINprobe X. In addition, it can be used as a simple standalone CAN/LIN gateway.

  • Data output to CAN (identifier is configurable)
  • LIN and CAN baud rates are configurable
  • Extension per logger:

    • Max. 5 LINprobes (10 additional channels) for GL1000/GL2000 family
    • Max. 7 LINprobes (14 additional channels) for GL3000/GL4000 family
    • Max. 5 LINprobes (10 additional channels) for GL5000 family

  • Export of LIN frames in many other formats, e.g. ASC, BLF, MDF
Afficher plus

Time-synchronous recording of MOST150 data can be done with the loggers of the GL3000/GL4000/GL5000 family and the GLA150 module. The GLA150 enables the very fast data transfer rate for MOST. 
The GLA150 is the first MOST150 logger interface that is listed by the MOST Cooperation as MOST compliant.


Highlights:

  • GLA150 is based on the proven Vector MOST150 interface VN2640 for CANoe and CANalyzer
  • Recording of the control channel and the asynchronous channel with MOST data packets (MDP) as well as with MOST Ethernet packets (MEP)
Afficher plus

LOGview lets you graphically display data from selected signals during logging as well as display text-based information.

 

Highlights:

  • LCD display with 128 x 64 pixels
  • Graphic window: 59 mm x 38 mm
  • Displays up to 8 lines of 21 characters each
  • 3 programmable pushbuttons
  • 16 independent display pages
  • 2 fonts with zoom (total of 30 font sizes)
  • Graphic functions: logging of straight lines, rectangles, etc.
Afficher plus

With the loggers of the GL3000/GL4000/GL5000 family and the VX measurement hardware, you can record internal ECU signals (variables, parameters) in parallel with bus communication. The ECU signals are measured using a POD (plug-on device). The connection of the logger to the VX module is by means of Ethernet and uses the XCP on Ethernet protocol.

 

Highlights:

  • XCP on Ethernet for higher data rates than XCP on the vehicle bus
  • Data transmission via DAQ mode
  • Support of ECUs with serial PODs

 

Go to VX1000 hardware web page for more information on VX1060

Afficher plus

The loggers of the GL3000/GL4000/GL5000 family are already equipped with 6 analog inputs. With the Analog Board you can expand the loggers to add 8 additional analog inputs. 

 

Highlights:

  • 8 differential, unipolar analog inputs
  • Voltage range 0 V ... 18 V
  • Resolution 12 Bit
  • Precision 0,2 %
  • Sampling rate 1 kHz for each channel
Afficher plus

Product Descriptions

Afficher plus

Do you have technical questions and are looking for suitable answers? Our KnowledgeBase provides the most important!

Afficher plus

Downloads

Related Sites

Afficher plus

vSignalyzer

Display, Evaluate and Document Measurement Data

Learn more
Afficher plus

CANoe

The state-of-the-art software for developing and testing individual automotive ECUs and entire networks.

More information
Afficher plus

VX1000

Scalable ECU Interfaces for Maximum Data Transfer Rates

Learn more
Afficher plus

vMeasure CSM

Easy Acquisition & Evaluation of Measurement Data

Learn more