News
2010-05-28: DaVinci Configurator 4.0.42 SP3
DownloadWith Service Pack 3, the following changes become effective:
New features:
- Support of Fold Containers in GCE to enhance clarity of GCE tree
- Support of Cut, Copy and Paste of containers in GCE
- Create validition log file in XML format where all executed validation rules are signed per ID with status OK or NOK
- Support use of variable names in folder specifications
- Extend parameter context menu with new item to undefine a parameter
- Enhance usability of assigning Package Licenses to projects
- Provide new menu item in Architecture view to revert module configuration to default with optional recommended configuration
- Enhance performance on loading projects and module editors
- Extend find parameter dialog with possibility to search for parameter comments
- Extend table context menu to insert or delete selected row
- Extend project menu with new item to test multiple configuration container names for uniqueness
- Read and write ECUC-Files with more than one AR-PACKAGE
- Support message numbers in all user messages
- Close nested messages automatically if they only contain uncritical severity messages
- Harmonize XSD validation with possibility to ignore shortname length violation
- Extend message context menu with item to open files with unknown file association
- Support AUTOSAR 3.0 Rev6 and 3.1 Rev4
- Support bit-operations in formula descriptions
- Status line reworked for better understandability
- Consider MinRelation of Containers, Parameters etc when creating new project
MICROSAR Generator
- Generation.log file format changed to XML
- Print user notification in module selection dialog for dependencies of modules that become deactivated
- Support starting generator with Project Assistent dpa file
- Provide option to switch off the creating of *.bak files during generation
- Save user code from Removed Code Area on restart of generation process
Fixed issues:
- Memory leaks removed
- The parameter help window is empty after insertion of a new row in a table
- The range of integer or float param is not displayed in the parameter help window
- Wrong short cut description in context menu for parmeter help found (should be Shift+F1)
- The project explorer becomes not synchronized in some case
- Set value to default fails with wrong pasted text in some case
- Jump-To-Error fails in some cases
- ECUC change detection shall not be executed if application is not focused
- Error messages of 3rd party generators are not well-formed if project path contains blank char
- Button for Hex/Dec format wrongly stays disabled in some case
- Access violation when changing editors in some case
- ECUC pretty print becomes not well-formed in some case
- Path specifications containing '#' cause errors on creating editors
- Tooltips are sometimes not readable
- An existing recommended module configuration is not considered when a module is added to the project
- Shortname naming algorithm skips free numbers
- The Project Assistant does not save ECUC before "update ecuc project..." is executed
- The error Messages raised from the Project Assistant are not displayed completely
- Relative project paths specified by the Project Assistant are not generated to the correct folder
- Loading a file can 're-enter' optional Containers
- Saving fails if 'MSXML 6.0 SP2' is used
- Performance issue when opening large comfort views
- Parameters $(EcucFile) and $(EcucFolder) are passed incorrectly to external Validator/Generator if 'Supply AUTOSAR Revision' option is used
[more info about DaVinci Configurator...]