Download
With Service Pack 1, the following changes become effective:
General Usage:
- Each installed Service Pack appears in the Windows Software list with a different name.
- Project selection dialog does show the last loaded projects sorted by the project directory
- The user is asked to save changed signal comments if a graphic window is closed
- Logging import converter supports database names longer then 32 characters
- Logging import converter handles flattened XLX files
- Some issues during printing of display windows are resolved
- The hotkeys Alt+<NUM> does work even the symbol explorer is activated
- Panel buttons can be selected if only a script is assigned
- There is a new macro to get the seconds of the current time
- The statistics funtion of the graphic window take into consideration all selected signals now
- The performance of the symbol explorer is optimized for large databases
- The Shell Extension for MDF files can be installed optionaly during the main installation
- Moving multiple signals inside the legend of display windows is possible now
- Some issues during loading of very big configurations solved
- There is a progress bar during loading large configuration files
- Issue in the Data window is fixed if the delete command is selected without a selected item
- ELF MAP files can be loaded even there is no version number defined
- The setup dialog of graphic and bar display windows restore the y axis setting if they are canceled
- The configuration name field of the status bar provides a context menu to load other projects or configurations
- Logging import converter supports CANcase XL logging format XLX version 2.01
- There is a project selection if the application is started in the program directory
- The symbol Explorer support Display Names
- A backup of project files is created if the project was created by an incompatible older application version
- Components of structures can be inserted into Bar windows
- Changed values of objects used a signal color will update the GUI
- New XCPsim on FlexRay-Demo( requires Vector FlexRay interface hardware )
- Canconv.dll: Support Condalo Log files
Measurement (expanded measurement data acquisition):
- Improved TAB navigation within the measurement configuration.
- Issue fixed when reading a big array (curve with 1672 axis points / data type: double)
- The filter in the signal list of the measurement configuration browser support filtering by measurement events again
- The default recorder file name is extended by the current date and time
- There is a message box if a measurement file could not be overwritten
- The result of the measurement configuration test is displayed in a message box
- Most of the columns of the measurement configuration browser provide a tooltip text now
- Stopping measurement with the ESC key can be disabled
- Saving Motorola signals into measurement files version 3.1 or greater is enabled by default now
- The measurement configuration browser provide a list of all events and all acoustic jobs now
- Disabled events are marked in the tree view of the measurement configuration browser
- Issue fixed at drawing the last value line in graphic windows during measurement
- Measurement configuration browser status bar display of selected signals is improved
- There is a new column displaying issues with measurement signals
- Test measurement configuration for all devices improved
- Display a warning when a measurement is started and a CANcab/CANpiggy is missing
Communication Protocol:
- Issue of the logging import converter fixed in case of importing XCP on FlexRay messages
- Crash with XCPonFLX project
- XCPonLIN: Support of the LIN piggy 6259 MAG
- XCPonLIN: Fixed response interpretation issue
- CAN device: error messages appear cyclically in write window if no CANcab is used
- XCP driver settings: Edit field of event channel number shows one byte only
- CCP/XCP: Fixed DAQ measurement configuration issue
- Da_Nidaq.dll: NI-6071-E does not work correct in differentiell mode.
- Support GPS receiver "u-blox 5"
- XCP (FlexRay, user defined networks): CANape crashes when a deactivated XCP driver tries to save a database
- The CHECKSUM_MAX_BLOCKSIZE overwrites the LOAD_CHECKSUM_GRANULARITY fixed
- XCP on Flexray: buffers which are not available are assigned if MIN_BUFFER_COUNT is used
- XCP on FlexRay: Added relative MIN_BUFFER_COUNT which adds specified number of buffers to the internally calculated ones
- XCP bypassing: Measurement buffer shows both daq and stim packets
- XCP: Automatic detection of a wrong map file name displays now both the wrong and the expected name
- Flexray: Fixed crash when the fibex file is replaced
- XCP on FlexRay: Added relative MIN_BUFFER_COUNT which adds specified number of buffers to the internally calculated ones
- Flexray: Fixed issues that an interface for monitor device could not be selected if no VN module was installed
- Fixed several XCP on FlexRay configuration and communication issues
Functions and Scripts:
- Script function Call() has a new option to wait until the executed program has finished
- The function UserQueryDialog is extended by some new options for text alignment
- Functions RecorderStart() and RecorderStop does work for multimedia signals (video)
- MDF comment text limitation does work even the text is created by a script
- User defined functions return zero if the function is left with cancel or return;
- Correct compiler error message in case of calling a user defined function with invalid parameters
- New IsNan operator to test for invalid floating point values
- Functions of the measurement configuration with mode "On Start" are executed only once
- A script assigned to a .NET Panel button is executed only once after pressing the button
- Load time of projects with a lot of functions is improved
- Added new scripting function CreateDevice()
- XCP: Upload the A2L content from the ECU memory location indicated by the result of EXCHANGE_ID (address)
- Fixed crash when testing measurement configuration being in offline mode
CANapeAPI:
- New API functions to StopScript/StopAllScripts implemented in IFlashmanager2 interface
- Fixed issue saving measurement objects using API modal mode
- CANape server: fixed issue with GetComplexParameter
- Issue fixed when the function Asap3Exit was called
MATLAB/Simulink Support:
- The MATLAB/Simulink measurement object dialog provides a button which will create a device to calibrate the model.
- Multiple usage support for CANape RT-Target generated MATLAB/Simulink DLLs.
- Matlab API: issue fixed when using read/write API-functions by address
- Matlab API: It should be possible to create a device without going online
- File comment text exported to MATLAB files is not limited to 255 characters
- Matlab API: Added function CANapeCreateModuleOnOffline(), WriteMemory(), ReadMemory()
Database:
- ASAP2 keyword NO_FORMULA is used for variables without a conversion rule
- An issue of the database editor after deleting variables from the search dialog is resolved
- Changes of the MAP file settings are taken into consideration without restarting the ASAP2 Editor
- Issue of the ASAP2 Editor is fixed if a Rescale or Curve axis
- Fixed issue that deletion of optional commands in the a2l file was not detected by CANape
Data Management (optimized calibration data management - CDM Studio):
- Binary parameter sets files will now be saved in the global par-file directory, if only the filename is given without of path. If the file name has a relative path, the path will be appended to the global par-file directory.
- Correction in check address overlapping between source address ranges and target address in checksum calculation library. (first byte of target is ignored)
- Complete the post process steps after closing CDM-Studio
- Improvement in handling CDF20 and PaCo specific data (SW_CS_FIELDS are now visible)
- Fix in handling user defined filter property dialog (now the correct property dialog will be opened)
- Fix in PAR file reader. (handle invalid files correctly)
- Performance improvements for variant codded Paco files
- New option for MOTOROLA-S-Record files to define the used address record type (16-, 24
- or 32-bit)
- Support insert parameter to a calibration window during measurement using the main menu item or the defined hot key (F8)
- Fix in merge parameterset feature in CDM-Studio
- Fix in "Save all calibration windows" feature: All curves from a calibration window are saved. Not only the active.
- Usability improvements in edit dialog of "attribute based" filters
- New option to file format INTEL-HEX which disables the creation of the offset record type 02
- Calculate the minimal offset depending on the referenced conversion rule
- Fix in PAR file reader: Comment lines > 128 chars are accepted. (The main comment can have unlimited line length, but for standard fields only first 32 chars are considered)
Offline Analysis:
- Support fast move (Shift + Alt) of the difference marker within the GPS window.
- CANape RT-Target: Generation of data type dependent min/max limits if min/max is defined as -Inf/Inf.
- Support of conversion rules for signals from BLF files if the database description has two conversion rules
- The performance is optimized if a measurement file is unloaded in the measurement file manager
- Both measurement markers can be moved syncronous using Drag&Drop with the right mouse button
- Issue with recalculation of virtual MDF signals in case of replaced input files is resolved
- MDF library supports sorting of MDF files with a too high cycle counter
- A proper error message is shown if a MDF file with a format error is loaded
- There is a progress bar during saving measurement files from the display buffer or from display windows
- Errors during resolving MDF comment field macros are signaled in the GUI
- Virtual file signals are recalculated only if some settings are changed inside the measurement file explorer
- There is no limit any longer if a measurement file is loaded into the measurement signal displays
Diagnostic (more extensive diagnostic options):
- Application note exists how to display DTCs in Grafic Window
- Issues with environment data fixed when overwriting UDS fault memory requests
- Added missing context menues in OBD window
- Toolbar buttons of diagnostic windows can be executed via context menu and shortcut
- Issue with Fault Memory Window fixed when changing the database language via the diagnostics driver setup dialog
- Copy to clipboard issue fixed in OBD window
- OBD window: show trace area button changed
- OBD window: issue with missing CANcard fixed
- Support of Prodis MCD-3D server (Vers. 22120)
- Usability of automatic script creation (from templates) in diagnostic console improved
- Now byte arrays are supported for diagnostic driver measurement/calibration objects
- Support of CANdela 6.0 diagnostic databases
- Support of CANapeScript extension *.cns in diagnostic console
- Fault memory window (MCD-3D): Support for configurable fault memory requests
- Default fault memory requests provided in Fault Memory Window in case of DSA PRODIS.MCD server
- Fixed issue in automatic diagnostic macro creation
- OBD window: Added buttons to select all or deselect all listelements
- Diagnostic driver: Now complex parameters are also written to qualifier overview file
- Diagnostic console: Update Byte:Bit Position for complex parameter fixed
- OBD: Support 29 bit ID´s and CAN baudrate 250000
- MCD 3MC: When adding a object to measurement list object has invalid raster
CANditoFlash (more flexibilty):
- Support of ODX-D
- use a generic CDD/ODX file
- Allows to create a flash container

Contact