Version History
2007-10-12: CANape 6.5 SP1
DownloadWith Service Pack 1, the following changes become effective:
General:
- GUI harmonisation for CANditoFlash
- Improved CPU load distribution on multiprocessor systems
- The former "Advanced Multimedia" feature "Shift multimedia signal for offline evaluation" is always available now
- Visibility of the undocked symbol explorer is assured
- Axis scaling keeps unchanged when signals are moved from one display window to another
- Fixed partial loading of windows which were displayed on multiple pages
- Fixed problem in non modal ASAP3 mode (query message for "Save Configuration" on exit)
- Fixed problem with Macros for Text To Speech
- Fixed Problem with curve windows and more than 10 curves
Measurement:
- Saving a measurement label list is possible even if no device is selected
- Curves with one column and multiple rows are now always handled like array signals
- The logging file of the write window is completely written when measurement stops
- Fixed issue regarding default measurement modes listed in measurement list
Calibration:
- Indirect modified parameters that are in the measurement list, are not updated until their new value is downloaded to the ECU
- KWP2000 on K-line: KW_Standard.dll now supports parameter calibration while measurement is running
Flash Programming:
- Use seed&key dll when flashing via CCPflash.exe
- Possibility to reduce STmin to speedup flashing
- CCP/XCP: Unlock required protocol resources for flashing
Database Editor:
- Sort order of the database explorer lists are saved individualy for each object type
Functions and Scripts:
- Path of a script added to the Extras menu can be relative now
- Measurement file signals can be directly accessed by functions to create virtual MDF signals
- Usability of the function browser "Intellisense" improved
Communication Protocols:
- Handle french keywords for memory segments in ASAP2 file
- Fixed problem reading FIBEX databases which contains CAN clusters
- Full support of J1939 for CANalyzer/CANoe ASC logging files
- Support of CAN DBC databases with multiple multiplexer signals
- Support of all LIN message types of CANalyzer/CANoe BLF logging files
- XCP: Support STIM only bypassing
- Improved FlexRay error messages
- Fixed stability problem when using the BusDoctor as FlexRay interface
- Fixed timestamp problem which occurred after resynchronisation of the FlexRay interface
- Fixed issue when importing A2L database which resulted in corrupt flash offsets
- XCP on FlexRay: fixed problem when deleting a FlexRay device
- XCP/CCP increased limit for LOAD_GRANULARITY to 65535
- XCP/CCP added trace coloring for CMD and RES packets
MATLAB/Simulink Support:
- Improved MATLAB/SIMULINK support for generated A2L files
- Project "save as..." does also store the MATLAB/Simulink model graphics
- Include the comment in the saved file when using MATLAB as target format
- Option to save maps in column direction when using in MATLAB format
- Fixed problem when creating a XCP module via the Matlab API
Data Management:
- Improved handling of variant coded parameters of the current device (C&P, save as...)
- Support sorting of items in CDM-Studio based on their address
- Added a new option to define a user defined filter: Filter the variant information only if the current group is variant codded
- Store display and sort configuration for the current device separate from the other settings
- Improvements in reading DCM and CVX file which contains parameters using a symbolic conversion table
- Restore the column order a reloaded parameter set file if the CDM-Studio is reopened.
- New menu item to adjust the column size of all opened parameter set files
- Support longer file names in the file open dialog of CDM-Studio.
- Restore the "All parameter set files" also as predefined filter in the open file dialog of CDM-Studio.
- Improvement in loading variant coded maps with standard axis
- Export filter contents with the current sort order from the GUI
- Improvement in handling parameters with overlapping addresses in the save action
Offline analysis measurement files:
- Improved signal selection from measurement files.
- A start time can be specified for importing ASCII measurement files.
- A time unit (factor) can be specified for importing ASCII measurement files.
- Command line option -M opens a measurement file without a signal selection dialog
- The comment in Diadem export files is checked for unsupported characters.
- The first Application Text Object in an CANalyzer/CANoe BLF logging file is used as comment for the MDF file.
- Measurement files loaded inside the measurement file manager are loaded permanently.
- Display FlexRay signals from CANalyzer/CANoe logging files.
Diagnostic:
- Fixed problem in CANape scripting regarding diagnostic response handles in case of mixed physical/functional addressing usage
- Fixed problem with CANape scripting command DiagSendRequest() in case of raw messages if no diagnostic database is used
- Performance improvement building the service tree of the diagnostic console window
- Fixed problems regarding bit field handling of CANdela service parameters
Map Reader:
- ELF mapfile reader supports bit structures correct now.