Version History

2006-07-17: CANape 6.0 SP1

Click here to download

General Improvements :
  • Support of new linker map format Microsoft VC8
  • Optional turn off acoustic feedback of multimedia signals before measurement is startet
  • Save the configured view (sort order) of the measurement list
  • Possibility to set the process priority during measurement.
  • Usage measurement start time in the MDF file header of CANalyzer logging files (BLF)
  • Value Block: Allow to copy value blocks with different dimension into another (MATRIX_DIM problem)
  • New Function to open (execute) the menu items from scripts
  • Align Virtual MDF signals to trigger
  • New array index form 'array.0.0' in scripting language
  • DBC Export for CANcaseXL Log: Support of CCP 1.01 and additional improvements
  • Datalogger mode: Ignore INIT_RETRIES parameter.
Drivers / Interfaces:
  • XCP: Support event channel priority
  • XCP on LIN: Support XCP on LIN 1.3
  • XCP on LIN: Support NAD to be part of IF_DATA
  • XCP via Serial: Support of two or more serial ports
  • Support of CRC-32 checksum with XCP
  • NI-DAQmx: Support of cyclic data acquisition
Diagnostics:
  • Diagnostic macro recording supports new qualifier syntax.
  • Diagnostic: Displaying information in case of response parse error.
  • Diagnostic: Display message in write window if Vector CAN hardware configuration has been changed
  • Diagnostic: Display warning message if DiagSendRequest(request, SPR) is send and SPR isn't supported by that service
  • Support measurement and calibration of diagnostic response and request parameters an case of ODX
  • Diagnostic driver: Calibration windows and scripts consider  the audience setting (user dependant set of diagnostic diagnostic functions)
  • Enhanced diagnostic scripting to support functional addressing
Data Base Editor:
  • Extended plausibility check for bitmasks in database editor
Other issues:
  • Optimized redraw of graphic windows in scroll mode
  • Destination folder can be selected for loading a zipped project
  • Editing components of a record layout works correct now 
  • Bitmasks in ASAP2 file for non integer values are ignored now
  • After changes in the database the view update works correct now
  • Address extension input in database dialog is in HEX format now
  • Assign multiple signals to a partial database  (multi selection of signals )
  • Settings of ATF import converter are saved now
  • Proper handling of measurement mode filter in measurement list
  • Correct verbal conversion rule is used now when adding enums from an IEEE map file
  • Changing the input variable of an existing Matlab/Simulink model works correct now 
  • MDF Batch converter works also without sort flag now
  • Symbol Explorer works correct now after replacing a huge MDF file in Measurement File Manager
  • Counter macro in MDF File Path works correct now
  • Map file directories different from current working directory work correct now
  • Loading of parameters during measurement works correct now
  • Selection/Focus in database editor is restored after changing the application
  • Existing projects with large number of GDI objects can be loaded again
  • Drag&Drop of signals from a graphic window to another page works correct now
  • Filter dialogs in CDM-Studio work correct now
  • Update problems in Calibration windows are solved
  • Load of database on start of CDM-Studio
  • Diagnostic Console: enhanced check of request service before submitting( Are the symbolic service parameter values are valid ? ).
  • Take conversion rule for displaying signals from a file using the measurement objects from file.
  • Proper notification in diagnostic console, if macro ended.
  • New aliases for scripting functions( DiagGetDbName for DiagGetCddName and DiagGetVariant for DiagGetCddVariant ).
  • Change dimension via interpolation denied if dimension is fix
  • Using the block measurement mode, signals from ODT messages greater then 8 kB can be saved into MDF
  • Close Write window during measurement enabled
  • CCP: include SET_SESSION_STATUS command in CCP-DBC configuration
  • KWPonCAN: Option to accept/ignore the A2L  IFDATA settings without confirmation
  • Graphic window: Support command "fit signals on top of each other" to common axis signals
  • Improved handling of  inconsistent CDDs
  • FlexCard II is available in user interface
  • XCP on LIN: CANape go online on starting project
  • Measurement cursor should display values hexadecimal if the display use hexadecimal
  • Multimedia window: Show live video after measurement