Version History
2011-07-18: CANdito 5.0 SP5
Download
With Service Pack 5, the following changes become effective (SP1 to SP3b are contained):
User Operation and Display:
- Fixed issue during partial loading of functions with compile errors from configuration files.
- The text display window handles default column width greater then 32 characters properly.
- Script function call() also execute binaries which are located in the sytem search path.
- Fixed issue if a measurement list filter using database groups is modified.
- The script function SetCurrentDevice() can be used to remove definiton of the current device.
- Fixed issue if more than expected files are selected for a measurement file export converter.
- Fixed issue if the application is started using a 8.3 DOS file name.
- Resizing of display windows is possible even the window is maximized on another display page.
- Rename and fix of script function DiagExcecuteJob() into DiagExecuteJob().
- Fixed issue during initialization of dynamic managed main menu entries.
- Display the raw value of signals in graphic windows even the raw value is mapped to a status table entry.
- Fixed issue which may have truncated the project file if the same project was reloaded after close.
- New switch to display the legend of the numeric array display window which is hided by default.
- Skripts added to the task manager are not recompiled at start if only the current device has changed.
- Fixed issue in case of changing the font in the function browser settings.
- Parameter and signals of the current configuration without a database description are marked with a specific icon, e.g. to identify them in the search result of the Symbol Explorer.
- Performance improvements (Open DeviceExplorer window).
Communication Protocols:
- Fixed issue which prohibited creation of analog devices.
- Fixed timestamp issue when using CAN channels from VX1121.
- Fixed CANextender device configuration issue.
- FlexRay: Improved handling of null frames in the static segment.
Measurement Data Acquisition:
- Changed logical channels are stored accurate in the next measurement files.
- The detection of low memory in case of storing many measurement data in the display buffers works on systems with more then 4 GB.
- Fixed issue in case of measuring an empty string.
- Fixed issue with splitted MDF3 measurement files with more then 256 data groups during measurement.
Offline Analysis of Measurement Files:
- Support of conversion rules for MDF objects as input for MATLAB/Simulink objects and functions.
- MDF merge converter handle files if first measurement value time stamp is zero.
- MDF merge/split converter handle MDF files using a offset for time channels.
- MDF merge converter merge files with different sample reduction blocks (sample reduction is removed).
- The MATLAB export converter provide measurement files containing structures.
- Fixed some issues during printing of signal names and indexes.
- Printer selection on Windows Vista and Windows 7.
Database:
- Fixed issue with LIN databases containing sporadic frames and no event triggered frames.
- Bus monitor databases are not marked as modified if the properties dialog of groups is closed with OK.
Automation:
- Fixed function DBObjectClass.get_Item(SignalName)
- Fixed macro based MDF file name generation.
- Increased maximum length of string parameter for function Asap3DiagSetStringParameter.
Diagnostics:
- Fixed "Tester Present" issue for functional devices.
- Accelerated flashing.
Data Mining:
- Boolean expressions using edge functions are never trigger at the first value.
- Fixed issue if Data Mining Explorer is closed and a deleted analysis is restored.
- The extension .DMR is added to Data Mining result files even the file name template contains another extension.
- The calculated values of virtual file signals can be accessed by scripts.
more about CANdito...