Version History
2011-04-19: CANape 8.0 SP5b
Download
Additional fix in SP5b: Updated version of the EffectiveODX Viewer
With Service Pack 5 (Build 50), the following changes become effective (SP1, SP2, SP3, and SP4 are contained):
Improved User Operation and Display
- A video device is disconnected if it is unplugged.
- A MATLAB/Simulink object associated device can be deleted also if the same input object is used multiple times.
- Windows 7: File dialogs are always using working directory as initial directory.
- Windows 7: Improved functionality of hyperlinks in CANape online help.
- CANconv: Fixed issue which mixed messages from different logical channels into same MDF channel for J1939 or FlexRay.
- Improved import of CANape configuration files.
- CANape script function "Exit()" is reported in DEBUG_LOG file.
- Improved displaying bits within digital window.
- Measurement can be started though MDI window is undocked.
- Saving of triggered measurement files has been optimized.
- Improved multimedia sync signal adaption which comes from BLF file.
Communication Protocol
- XCP: Optimization of upload procedure.
- XCP on Ethernet: Support of IGNORE_CTR_FAULTS.
- Fixed issue for KWP2000 usage without license available (offline mode).
- Fixed buffer overflows when measuring large amount of data.
- Reduced MDF file size for FlexRay measurements.
- LIN: Added support for CANcard XLe.
- FlexRay: Fixed issue which affected MDF file generation when measuring null frames.
Extended Measurement Data Acquisition
- Multimedia signals with multiple trigger points can be stored in one MDF file.
- Improved saving of signals to MDF via script function "SaveDisplayBuffers" or via pop-up menu in measurement window.
- Improved saving of signals to MDF via pop-up menu in measurement window concerning start time.
- XCP: Improved memory allocation for large measurement configurations.
- XCPonEthernet: Improved memory allocation in case of measurement with high data rate
Offline Analysis of Measurement Files
- Project management: Measurement files referenced by file channels are only listed once.
- MDFLib: Support of files with INT64 timestamps, possibility to correct additional records.
- MDFLib: Improved creation of MDF 3.2 files concerning timestamps.
Database
- Improved import of structures from CDD to A2L.
- ASAP2 Editor: Improved saving of units for standard axis.
- Improved support of map files containing long record names (>128 characters).
- ASAP2 Editor: Updating the database addresses updates the structure tree.
- CCP/XCP: Improved funtionality of option "Reconnect after flashing".
- Improved saving of conversion tables to database.
- Improved saving of A2L if AML contains an ENUM value with more than 2 Bytes
- ASAP2Editor: Improved handling of A2L files containing empty structs in IF_DATA section
Calibration Data Management (Parameter Sets & CDM Studio)
- Display a message if an A2L file is loaded into CDM-Studio which includes a CHARACTERISIC with wrong ALIGNMENT.
- CDM-Studio: Display the correct tool tip (selected Filter(s)) in current device column. For 'snapshot' columns the snapshot timestamp appears as tooltip.
- EXCEL-Report now displays no value instead of an invalid value if the parameter set has no parameter. Also it displays the parameter name in the correct column.
- Support save parameter set as MatrixX (*.ms) file.
- In Case of CDF20 file deny copy&paste of variant coded parameter if target parameter set does not support variant coded parameters.
- Improved handling of A2L files which contains not correctly described parameters, e.g. if a parameter refers a curve axis as x-Axis but this object is declared as common axis.
- Fix in detail window "format specific information" in case of multi selection and if the parameter set is based on PaCo format.
- Update the filter content correctly if the option "Display referenced and defined parameter" is changed.
- Set the read only state of the 2D/3D detail window correctly if the CDF20 complete state option is changed or the state itself is modified.
Extended MATLAB/Simulink Support
- The Model Explorer displays also parameters without write access.
Calibration
- Fixed KWP2000 bit calibration issue.
- Fixed issue which affected calibration memory initalization in case hex file name is derived from database.
- Improvement in update calibration window content to support calculation of MDF signals.
- The automatic snapshot creation after „Flash | Save parameter set + merge in binary file„ is executed correctly.
- Improved handling of calibration history to support changing of parameter of type MAP or CURVE if a measurement is running.
- Corrected visualization of state of increment "+" and decrement "-" buttons in the calibration window.
- 2D/3D window: save setting "Different Z-axis scale" to configuration file.
Diagnostics
- Improved CANditoFlash stability.
- Suppressed unnecessary warnings when flashing via diagnostic protocols.
COM Interface
- Fixed issue when reading data via COM interface.
Known Issues
- CCP: Write/read A2l Parameter BYTES_ONLY
- Seed and Key: No error handling of floating point calculations.
Advanced Multimedia
- Support of same CAN signal names of different CAN messages as object reference for gfx object properties: :$CAN_Message$CAN_Signal
- Access to ML/SL object output structure components from gfx object properties.
- Corrected adjustment of graphic object group buttons in Multimedia window.
more about CANape...