Version History
2008-09-24: CANape 6.5 SP4
DownloadWith Service Pack 4, the following changes become effective (all changes of
previous Service Packs are contained):
General:
- Fixed issues in case of working with a secondary monitor.
- More then 11 common y axes can be used in graphic windows.
- System resource consumption improved in case of big configurations.
- Fix some issues during graphic window redraw on multicore computers.
- Performance optimization during reading very large project or configuration files.
- Fix some issues in case of too long strings.
- Time axis labels of graphic windows are drawn exact in case of absolute time.
Communication Protocols:
- Trace window can display data bytes of large XCP messages now.
- Support LIN piggy 6259 and 7259 MAG.
- Fixed communication issue for GPS receiver "u-blox 5".
- XCP on FlexRay: Fixed issue "CANape does not assign buffer if the requested bandwidth is < than 1 Byte/cycle".
- Suppress popping up error messages in data logger mode.
- Various improvements for XCP on FlexRay.
- Fixed issue related to DAQ event triggered function execution.
- Fixed byte order issue when saving parameter sets.
- Various improvements for XCP on FlexRay logger configuration.
- Improved error reporting for FlexRay VN hardware interface.
- Fixed tracing issue for XCP protocol details.
- Fixed configuration file issue for CAN loggers.
- Fixed XCP protocol parameter configuration issue.
- Improved generic XCP driver interface.
- Improved BLF file logging for offline analysis.
- Improved Bypassing stability and real time performance.
- Added support for Microsoft PDB Map Format.
- Improved synchronization for variant dependent calram segments.
Multimedia:
- Support cutting of video files in case of a triggered measurement.
- Fixed issue in case of stopping a measurement from a function, if multimedia signals are measured.
- Performance optimization during saving of AVI files at stop of measurement.
Database Editor:
- Support if ASAP2 files containing IF_DATA_CANAPE_EXT Version 2.00.
Data Management:
- Correction in Handling of Color option in CDM-Studio.
- Consider the maximum dimension in case of Copy and Paste in CDM-Studio.
- Correction in parameter explorer to handle database exchange if OSEK Monitor is enabled.
- Usability improvement in application history overview of CDF20 and PACO files.
- Improvements in CDF20 support.
- Correction in Handling of maps and curves and value blocks.
- Correction in handling of SHIFT-Key in the CDM-Studio list view.
- Improvements in handling the application history of PaCo files.
- CDM: post-processing of INTEL-HEX format only worked with an absolute path for the configuration file.
Offline Analysis Measurement Files:
- ASCII export converter can export string signals with more then 50 characters now.
- Import converter for logging files:
- Improved support of BLF files containing FIBEX FlexRay messages with PDUs.
- Support of XCP on FlexRay DAQ messages.
- Support of XLX format 201, improved recognition of corrupted log files.
- Fixed issue with multiple conversion rules for LDF databases.
- Changed determination of start time, new option to include UTC time (MDF 3.2).
- Changed option for support of combination of a verbal and a linear conversion rule.
Automation:
- Fixed automation interface issue in calibration use cases.
- Fixed issue with reading big array (curve with 1500 axis points / data type: double).
Diagnostics:
- Now the qualifier overview export contains also complex parameters.
- Support for byte array parameters (diagnostic device driver).
- Possibility to control the DLC padding handling in the diagnostic driver setting dialog.
- Added possibility to switch between raw and physical reading calibration objects (COM interface).