2010-05-12: CANalyzer 7.2 SP3 incl. LIN, MOST, FlexRay, IP, J1939, NMEA2000, J1587
Download
With Service Pack 3 (update to 7.2 build 60), the following changes become effective:
General:
- Due to technical reasons, SP2 was integrated completely in SP3
- CANalyzer now also supports System Variables. With this data exchange between CAPL nodes and analysis windows is easily possible. Value tables are also supported by System Variables
- The combination of System Variables and Panels allows interactive control of CAPL nodes. Using keyboard short cuts is no longer required. Panels can simply be used to transmit values
- Panel-Editor Panels can be imported into the Panel-Designer for changes. Converting all Editor-Panels of a configuration into Designer-Panels is simply possible in a single step.
- The usability of the Graphics Window together with the mouse has been extended. Beside the possibility to move single curves directly in the view or with the axes, zooming is simply possible with the mouse wheel
- Together with the recent hardware drivers, the program can be used under Windows 7 64 Bit
- Eclipse can be used as editor for CAPL-Files
Diagnostic Feature Set:
- The new Basic Diagnostics feature supports definition of simply structured diagnostic services (UDS) and their transmission on the CAN bus. A description file (CDD or ODX) is not required. Furthermore basic diagnostics communication can be analyzed in the Trace-Window.
- Improved display of ISO TP frames in the trace window (truncation to 10 data bytes removed)
Option .LIN:
LDF Support
- The LDF parser now accepts the attribute channel_name defined as an identifier as specified in the latest errata sheet (see Typo018).
- The old definition as string is stilled supported due to compatibility reasons.
LIN File Editor
- Full version now able with all CANoe/CANalyzer variants
- LDF templates for LIN1.3, LIN2.0 and LIN2.1
- Smart insertion of LDF definitions for LIN1.3, LIN2.0 and LIN2.1
- NCF templates for LIN2.0 and LIN2.1
LIN Statistics Monitor
- Copy to clipboard via CTRL-C and context menu "Copy to clipboard"
Option SCOPE for LIN:
- Supported max. buffer size increased to 1 MS (pro scope channel)
- Parallel to LIN acquisition of up to 2 additional scope channels (e.g. for the Rx pin signal and the ECU´s sensor signal)
- Trigger automatically activated on measurement start (deactivation possible via the configuration dialog)
- Highlighting and selection of triggered frame in Scope Trace
- Zoom factor no longer limited
Option .MOST:
- Support of MOST50: CANalyzer.MOST 7.2 now supports the MOST50 standard and allows access to the control channel and packet channel as a node or spy. Many practice-proven analysis features are offered, such as the Trace, Data and Graphic windows, and the function block monitor. The tool also provides filter options and the interactive generator block for stimulation of the MOST ring. For the most part, the programming interface has been kept identical too. The tool accepts existing CAPL programs and they can be re-used with minimal modifications. Optolyzer G2 3050e (also as variant "Production") is used as bus interface. A licence for the Optolyzer Integration Package from Vector is required. (The same OIP is also valid for the operation with an Optolyzer for MOST150.)
- MOST Panels (only available in CANalyzer Pro): With the new control "MOST Send Button" for the Panel Designer, MOST messages can be sent directly from panels.
Additionally, remote controls (OCI files) can be imported into the Panel Designer or, with the help of the utility "OCI2Panel Converter", be converted into the panel designer format. In CANalyzer, now panels also allow to control CAPL programs.
- The MOST System Viewer now displays the names of the ECUs and updates the display whenever the ring configuration changes. A statistic on the number of current MHP connection is also available.
- MOST High Protocol
- The MHP Observer now also handles test scenarios in which the same MHP connections are setup again and again.
- The events of the MHP Observer now can be configured to the MOST application filter (MAF). By choosing address information, function block, function id and operation type, including the use of wildcards, the filtering can be customized.
- The MHP modelling library can keep an MHP connection alive even without transmitting data.
- The function catalog import now also supports parameters of the type StreamSignal.
- Trace Window: The event filtering now also supports the display or hiding of all explicitly selected rows. Former versions extended the selection to all rows with events of the same types as contained in the selection.
- Synchronous channels: The option to stream the synchronous channels of the MOST ring into the PC was extended in a way that a single MOST node now can receive the data, process it and stream it back to the MOST ring at the same time. This allows for an online signal processing e.g. to create sound effects. A simple demo configuration is already included in the delivery. On request to MOST@vector.com, a workspace to create user defined signal processing DLLs can be provided.
Option FlexRay:
- Diagnostics
- PDUs in the dynamic segment can be received with a shorter payload length than defined in the database (if the PDU is the one and only PDU in the frame).
- PDUs with an odd payload length are handled correctly by the diagnostics stack.
- FlexRay ISO 10681-2 Transport Protocol DLL: Supporting an optionally 2nd ECU TP address
- VN Interface: Support of the trigger input of the VN interface (see Trigger Input VN Interface)
- FlexRay Filter Block
- Supporting Drag&Drop for configuring a filter
- New available functions in the context menu: Separate filters for the static & dynamic segment, one step configuration of the Update Bit for a set of selected PDUs
- FlexRay PDU Panel
- Support of multiplexors for signals
- Selection of values from text tables for setting a signal
- FlexRay Statistics Monitor: The monitor has been extended by some additional and valuable statistics: Utilization of the static segment, Utilization of the dynamic segment, Offset correction, rate correction and POC state
- Trace Window: If a valid data frame is not received completely, because of a too small reception buffer (i.e. consider the value of "MaxDynamicPayloadLength" for the FIFO of the FlexCard Cyclone II), then the payload length of the frame header is displayed and thereafter the received payload length in parenthesis: e.g. 64 (16)
- Other Improvements: Configuration of the localization for displaying some FIBEX properties (long name, description): in the dialog for the General FlexRay Options the desired language for displaying the values of these properties can be selected.
Option .IP:
- The PCAP file format is supported for replay and import.
- Trace window:
- The protocol "HTTP" is supported.
- Symbolic or physical values are displayed in addition to raw values in the detailed view.
- A new column "Packet Length" gives the number of bytes counted from MAC-IDs up to end of payload incl. padding.
- Sorting by length is possible.
- TCP packets with DoIP port but without payload are not marked as erroneous DoIP packets.
- Multiple DoIP packets in one TCP/UDP packet are displayed.
- Ethernet Packet Builder:
- Erroneous fields are indicated in section "Packet Information".
- Display and usability are optimized.
Option .J1939:
- The J1939 OBD-I/M Monitor supports sorting by timestamp.
- Trace window: The View Filter supports multiple selection again.
- Graphic and Data Window: Modification of SA and DA in message and signal edit dialog is corrected.
- Filter block: The dynamic filter blocks messages after ACL from another node.
- J1939 Scanner:
- Node names are displayed according to device names if they are available in the database.
- "Commanded Address" works again.
- J1939 Diagnostic Monitor (DTC Monitor):
- LampStatus=01b & Flash=10b (SAE reserved) is ignored for lamp indication.
- Keyboard control is improved.
- Actions triggered by individual buttons are adapted for multiple selection.
- J1939 Diagnostic Memory Access:
- Read/write access with large data amount is possible (without timeout).
- DM13 indicating "HOLD" is transmitted to 0xFF always.
- Object access supports SPNs which are not available in the database.
Option .NMEA2000:
- The sample configurations are revised.
- The GNSS Monitor supports environment variables of type float as third dimension.
- The GNSS Simulator transmits correct positions at transition from 23:59:59 to 0:00:00 (UTC)
Option .J1587:
- The GUI behavior of Parameter Monitor and Diagnostics Monitor is improved.
- For information, warning and error messages extended descriptions are available in the online help.
Option .CANaerospace: