Download
With Service Pack 1, the following changes become effective:
General Usage:
- Each installed Service Pack appears in the Windows Software list with a different name.
- Project selection dialog does show the last loaded projects sorted by the project directory
- The user is asked to save changed signal comments if a graphic window is closed
- Logging import converter supports database names longer then 32 characters
- Logging import converter handles flattened XLX files
- Some problems during printing of display windows are resolved
- The hotkeys Alt+
does work even the symbol explorer is activated - Panel buttons can be selected if only a script is assigned
- There is a new macro to get the seconds of the current time
- The statistics funtion of the graphic window take into consideration all selected signals now
- The performance of the symbol explorer is optimized for large databases
- The Shell Extension for MDF files can be installed optionaly during the main installation
- Moving multiple signals inside the legend of display windows is possible now
- Some problems during loading of very big configurations solved
- There is a progress bar during loading large configuration files
- Problem in the Data window is fixed if the delete command is selected without a selected item
- ELF MAP files can be loaded even there is no version number defined
- The setup dialog of graphic and bar display windows restore the y axis setting if they are canceled
- The configuration name field of the status bar provides a context menu to load other projects or configurations
- Logging import converter supports CANcase XL logging format XLX version 2.01
- There is a project selection if the application is started in the program directory
- The symbol Explorer support Display Names
- A backup of project files is created if the project was created by an incompatible older application version
- Components of structures can be inserted into Bar windows
- Changed values of objects used a signal color will update the GUI
Measurement (Expanded measurement data acquisition)
- Improved TAB navigation within the measurement configuration.
- Problem fixed when reading a big array (curve with 1672 axis points / data type: double)
- The filter in the signal list of the measurement configuration browser support filtering by measurement events again
- The default recorder file name is extended by the current date and time
- There is a message box if a measurement file could not be overwritten
- The result of the measurement configuration test is displayed in a message box
- Most of the columns of the measurement configuration browser provide a tooltip text now
- Stopping measurement with the ESC key can be disabled
- Saving Motorola signals into measurement files version 3.1 or greater is enabled by default now
- The measurement configuration browser provide a list of all events and all acoustic jobs now
- Disabled events are marked in the tree view of the measurement configuration browser
- Issue fixed at drawing the last value line in graphic windows during measurement
- Measurement configuration browser status bar display of selected signals is improved
- There is a new column displaying problems with measurement signals
- Test measurement configuration for all devices improved
Communication Protocol:
- Issue with the logging import converter fixed in case of importing XCP on FlexRay messages
- CAN device: error messages appear cyclically in write window if no CANcab is used
- Support GPS receiver "u-blox 5"
Functions and Scripts:
- Script function Call() has a new option to wait until the executed program has finished
- The function UserQueryDialog is extended by some new options for text alignment
- Functions RecorderStart() and RecorderStop does work for multimedia signals (video)
- MDF comment text limitation does work even the text is created by a script
- User defined functions return zero if the function is left with cancel or return;
- Correct compiler error message in case of calling a user defined function with invalid parameters
- New IsNan operator to test for invalid floating point values
- Functions of the measurement configuration with mode "On Start" are executed only once
- A script assigned to a .NET Panel button is executed only once after pressing the button
- Load time of projects with a lot of functions is improved
CANditoAPI:
- New API functions to StopScript/StopAllScripts implemented in IFlashmanager2 interface
- Fixed problem saving measurement objects using API modal mode
- CANape server: Fixed problem with GetComplexParameter
- Issue fixed when the function Asap3Exit was called
MATLAB/Simulink Support:
- Matlab API: Problem fixed when using read/write API-functions by address
- Matlab API: It should be possible to create a device without going online
- Matlab API: Added function CANapeCreateModuleOnOffline(), WriteMemory(), ReadMemory()
- File comment text exported to MATLAB files is not limited to 255 characters
Database:
- Changes of the MAP file settings are taken into consideration without restarting the ASAP2 Editor
Offline Analysis:
- Support of conversion rules for signals from BLF files if the database description has two conversion rules
- The performance is optimized if a measurement file is unloaded in the measurement file manager
- Both measurement markers can be moved syncronous using Drag&Drop with the right mouse button
- Issue with recalculation of virtual MDF signals in case of replaced input files is resolved
- MDF library supports sorting of MDF files with a too high cycle counter
- A proper error message is shown if a MDF file with a format error is loaded
- There is a progress bar during saving measurement files from the display buffer or from display windows
- Errors during resolving MDF comment field macros are signaled in the GUI
- Virtual file signals are recalculated only if some settings are changed inside the measurement file explorer
- There is no limit any longer if a measurement file is loaded into the measurement signal displays
Diagnostic (More extensive diagnostic options):
- Application note exists how to display DTCs in Graphic Window
- Issues with environment data fixed when overwriting UDS fault memory requests
- Added missing context menues in OBD window
- Toolbar buttons of diagnostic windows can be executed via context menu and shortcut
- Issue of Fault Memory Window fixed when changing the database language via the diagnostics driver setup dialog
- Copy to clipboard problem fixed in OBD window
- OBD window: Show trace area button changed
- OBD window: Problem with missing CANcard fixed
- Support of Prodis MCD-3D server (Vers. 22120)
- Usability of automatic script creation (from templates) in diagnostic console improved
- Now byte arrays are supported for diagnostic driver measurement/calibration objects
- Support of CANdela 6.0 diagnostic databases
- Support of CANapeScript extension *.cns in diagnostic console
- Fault memory window (MCD-3D): Support for configurable fault memory requests
- Default fault memory requests provided in Fault Memory Window in case of DSA PRODIS.MCD server
- Fixed problem in automatic diagnostic macro creation
- OBD window: Added buttons to select all or deselect all listelements
- Diagnostic driver: Now complex parameters are also written to qualifier overview file
- Diagnostic console: Update Byte:Bit Position for complex parameter fixed
- OBD: Support 29 bit ID´s and CAN baudrate 250000
- MCD 3MC: When adding a object to measurement list object has invalid raster
CANditoFlash (more flexibilty):
- Support of ODX-D
- Use a generic CDD/ODX file
- Allows to create a flash container

Contact