Version History

2007-07-19: CANalyzer 6.1 SP2

Download

With Service Pack 2 (Update to 6.1 build 29), the following changes become effective, all previous service packs for version 6.1 are contained:

FlexRay:
  • Transmission of Wakeup pattern at measurement start (configurable in the hardware configuration dialog)
  • CAPL transmission function for PDU (FRSetSendPDU, FRUpdatePDU) and CAPL PDU Object (FrPDU)
  • The behaviour of the PDU update bits in CAPL can be configured (automatic reset after transmission, n times, ...)
  • PDU selection for the Coldstart helper slot
  • Support of the Busdoctor driver V 2.17 (automatic resynchronisation, mixed mode).
  • Reset of frame- and node states in the FlexRay Cluster Monitor with a toolbar Button.
  • Display of FlexRay error classes in the Bus statistic window (Syntax Error, Content Error, Boundary Violation)
  • The CAPL callback "OnFrPDU" returns the payload length in Bytes.
  • With active Nullframe filter all planned Nullframes will be filtered correctly.
  • The Coldstart helper of the VN3x00 can be used in the combined mode.
  • The driver version request fort he Busdoctor does not lead to a crash.
J1939/NMEA2000:
  • Improvement: Display always address 254 as NULL in Trace Window.
  • Reject J1939 configurations if there is no option J1939 available.
  • Fix undefined attribute in NMEA2000 System demo.
  • Fix data length issue with Diagnostic Memory Access dialog.
J1587/1708:
  • Fix issue with channel assignment.
  • Fix CANalyzer/CANoe crash in case of accessing not supported Kvaser hardware.
  • Fix signal address problem in Data Window