Versionshistorie

2009-01-07: CANape 7.0 SP2

Download

Die folgenden Änderungen werden mit Service Pack 2 (Update auf 7.0 Build 20, SP1 ist enthalten) wirksam:

General Usage:
  • Symbol Explorer: "Search result" can be sorted by column "type"
  • The name of the current loaded configuration is not changed if loading of a invalid configuration file was denied
  • The sort order of inserted signals in display windows is top down again.
  • Symbol Explorer: The context menu does work on a secondary monitor with negative pixel position
  • Elf Linker map files with more then 16000 compile units (source files) are supported now.
  • Fix compatibility issue when loading a project containing a LIN device created by CANape 5.6.40
  • No range info tooltip displayed for string parameters any more
  • MCD-3D: Fixed problem of project selection that occured when cancelling the MCD-3D device creation
  • Improved T-Systems MCD3 server integration (apply system settings on server startup)
  • Setup: Users having no administration rights are able now to modifiy the assignement of logical hardware channels
Measurement( Expanded measurement data acquisition )
  • Support of an external time master. The time master can be activated in the device configuration
  • System event "Measurement Start" can be used to start a triggered recorder
  • CCP and XCP error events can be used to trigger a recorder.
  • An error message is reported to the write window if automatic start of measurement is not possible because of missing Licence
  • Recorder is stopped after sum of maximal stop time and post trigger time if the stop event does not occur
  • Measurement functions executed "On Key" do not break the measurement if they show a dialog
  • The type of conversion rules can be displayed in the GUI (Column "Type of Conversion")
  • Virtual database signals or measurement functions are inserted with a valid default measurement mode
  • Improved support and usability of Tricore measurement use cases using VX1000 as measurement interface
Communication Protocol
  • J1939 filter settings of CAN devices can be defined individual for each device now
  • ECU signals measured by XCP on FlexRay are created in the same way by the BLF import converter as by CANape during measurement
  • Support Seed&Key binary algorithms for multiple ECUs
  • Take care of maximum checksum block size when flashing memory
  • Added explicit configuration of initial memory page for CCP-"InitRam by tool"
  • XCP driver settings: usability improvements
  • Do not import CODE segments from A2L as calibration memory segments
  • FlexRay: Fixed interface hardware access issue
  • FlexRay: Fixed logging config generation for XCP
  • Measurement is not started anymore in case of DAQ configuration error
  • CCP: Improved error handling during measurement
  • Fixed issue saving an incorrect A2L file when it contains XCP on FlexRay communication parameters
  • XCPonFlexRay: Truncate long A2L signal names if they are used in a logging config file
  • Support XCP EV_SESSION_TERMINATED
  • XCP on FlexRay Bandwidth management: Support transmission rate prescaler
  • Report invalid conversion rules when generating logging configurations
  • Fixed issue which generated invalid measurement data for XCP on Ethernet in case of MAX_DTO > 252
  • Fixed data corruption issue relevant for Bypassing use cases in conjuction with arrays
  • Added some XCP communication errors to the list of known errors
Functions and Scripts
  • A UserQueryDialog opened by a script is suppressed if the application is started in silent mode (Commandline option -q)
  • Fixed problems when changing tester present state from scripts
CANapeAPI
  • Fixed problems for dual core computers on ASAP3 translator logfile creation
  • Fixed problem with incorrect Task ID on nonmodal ASAP3 mode for duplicate measurement objects
  • Fixed problem with CANape TCP server API function Asap3GetFifoLevel()
MATLAB/Simulink Support
  • Multiple selection can be used during assigning signals to parameters of a MATLAB model.
  • Fixed issue at Matlab API library
Database
  • The read only flag of standard axes can be set in the ASAP2 Editor now
  • The size of String variables is shown in the ASAP2 Editor variable properties dialog.
  • Updated version of FIBEX-Explorer
Data Management ( Optimized calibration data management(CDM Studio) )
  • Display parameter value with ASCII format in the numerical detail window of CDM-Studio in the correct way.
  • Fix in comment import for PAR file format in the property dialog in CDM-Studio
  • Write the correct device information in the PAR file if a PAR file is saved within the CDM-Studio
  • Additional column in the EXCEL report component in CDM-Studio to report the A2L comment
Offline Analysis
  • Support visualisation of GIN Multilog data files (CLF files)
  • Partial loading of virtual signals does not duplicate the parameter list for each display of the signal
  • ECU signals measured by XCP on FlexRay are created in the same way by the BLF import converter as by CANape during measurement
  • The time grid values created by the ASCII Export for measurement files are rounded depending on the grid raster
  • When importing CAN logging files, CAN remote frames are not imported by default (added option to enable this feature)
  • Display structure component values after load of measurement files
Diagnostic ( More extensive diagnostic options )
  • OBD and Variant Coding diagnostic windows can be exported as bitmap now.
  • New context menu "Create OBD Report..." available in OBD Window
  • The OBD window now handles freeze frame scans for ECUs that do not send a response for a unsupported frame number
  • OBD: Fixed problem with extended (29 bit) CAN IDs for functional request messages ($18DB33F1)
  • OBD: Added progress bar display while performing the OBD network scan
  • New "Create report…" function to export the OBD data to an XML file
  • Improved performance of diagnostic console service tree display
CANditoFlash (More flexibility)
  • Communication parameters can be optionally imported from ODX or CDD file
  • No separat tool needed any longer to create a flash container
  • Edit the configuration file that controls/parameterizes the flash script, insert the configuration file to the flash container