Versionshistorie

2007-06-06: CANdito 2.0 SP3

Download

General Usage:
  • Scripts can be added to the toolbar now.
  • Change company name on the registration dialog.
  • Fix problem with unsorted measurement object list after the name of a measurement function has been changed.
  • Fix problem for command "change dimension with interpolation" in case of a invalid map or curve.
  • Fix problem in the measurement list if letters are entered.
  • Saving the default settings does work for graphic windows again.
  • Maximizing a display window does maximize the selected window and not a second minimized window.
  • Closing the properties dialog of a database object in read-only mode with "OK" will not set modified flag.
  • Correction in copy and save a string value to PAR file.
  • Fix read problem of settings for user defined filters.
  • Functions with virtual signals assigned to input parameters are executed regardless of the order in the measurement list.
  • Fix problem with the measurement cursor in empty text windows if "Strg" or "Shift" is pressed.
  • Fix problem with non modal error message box during loading a configuration, if the symbol explorer is open.
  • Curve without axis can be inserted into an existing calibration window.
  • Addon Tool menu entries can be defined in the registry.
  • Fix problem with location of the context menu for multiple monitor systems.
  • Fix problem with script function LoadConfiguration().
  • Fix problem for the ATF-Converter when converting an mdf-file with the script function ConvertFile().
  • Fix problem with duplicated global variables in the function editor.
  • Fix problem if the info dialog is open and the permanent offline mode is changed because a inserted/removed license.
  • Measuring mode "On Start" does save always one value in case of a triggered measurement.
  • Support trigger condition on same named CAN signals which are defined in multiple messages.
  • Display of physical value with measurement cursor is not restricted any more to min/max physical values defined in database.
  • Added possibility to suppress dialog "Adjustment of calibration ram" by executing default action.
  • Optimization of the logging converter for CANcaseXL log measurement files.
  • Do not show a trigger line in graphic windows after a measurement without a trigger.
  • Fix problems in case of logging J1939 messages with more then 8 data bytes into a BLF.
  • "Remark" can be saved for an "ASCII String" variable.
  • Calibration windows are updated now if a HEX parameter file is loaded and the ECU is offline.
  • Fix problem in the Measurement File Manager when closing dialog for an invalid virtual signal.
  • Fix some memory leaks caused by calling function of function DLLs with string arguments.
  • Function sizeof() does work for MDF file signals now which are not already created.
  • The datatype unsigned long does work in the function editor now.
  • Fix some memory Leaks during compiling scripts or functions.
  • Fix problem with invalid configured dependent parameters.
  • Fix problem when closing a configuration containing a array measurement object with a not complete measured axis.
  • Delete temporary files of imported CANalyzer logging files if the file device is permanent loaded.
Map Reader:
  • COFF reader outputs supports values if bit fields which cross byte borders.
  • Fix problem with invalid addreses read from elf file generated by MW EABI PPC C-Compiler.
  • Fix problem with ASCII string variables linked to an entry of an ELF map file.
Driver:
  • VCANTCP: Fixed data corruption problem.
  • Analog driver (IOcab): Prevented resetting values in calibration window upon refresh.
  • GPS driver: Corrected values of position/dilution, added additional satellite information.
  • NI-DAQ driver: Fixed problems with PCI-MIO-16XE-50.
  • Fix problem with CNP_CREATE_INI driver entries in an a2l-file.
  • A variant criterion can not be assigned to a database group that contains the associated selector.
  • Custom Audi K-line driver : Read access to calibration object led to suspend/resume of free running mode even if the values are cached.
  • Corrected format of blf log file created by CAN device.
  • Support of Transport Protocol in case of multiple CAN devices using J1939 CANdbs
  • Improved import of LIN ldf-files.
  • Fixed problems in CANdito when creating device using fibex-file.
MDF:
  • Display error message during MDF signal selection because a signal comment with more then 255 characters.
  • Save time range of a multmedia signal into a new MDF file does not modify the avi file link in the base multimedia signal anymore.
  • Support Integer time stamps with more then 32 Bit in MDF measurement files.
  • Fix problem with channel counter of MDF files if arrays are saved in one channel group or block measurement mode is used.
  • Fix problem during configuration of a virtual MDF signal if a not allowed parameter is selected which is already assigned.
  • Fix problem at reading or writing an Integer signal with Motorola Byte order in an MDF file and a bit offset.
  • Support J1939 BAM at converting BLF files into MDF files.
Diagnostics:
  • Fixed wrong "no interpretation possible" warnings for empty strings in the trace of the diagnostic console.
  • Changed text for physical ./. functional addressing from "Addressing Scheme" to "Addressing Mode".
  • If a response parameter value is invalid now additionally an according message appears (along with the raw hex value output).
  • CANape could crash when a diagnostics device was changed from physical to functional addressing.
  • The message box of the diagnostic console that warns in case of invalid parameter values was adapted for huge parameter lists.
  • Fixed bug that caused a crash after changing the communication interface of a diagnostic driver.
  • Fixed some wording problems in string resources of the diagnostic driver dialog.
  • Now it is possible to override the used fault memory requests also for the K-Line driver.
  • Optimized bus load in diagnostics driver during measurement.