Versionshistorie

2011-07-18: CANdito 5.0 SP5

Download

Die folgenden Änderungen werden mit Service Pack 5 wirksam (SP1 bis SP3b sind enthalten):

User Operation and Display:

  • Fixed issue during partial loading of functions with compile errors from configuration files.
  • The text display window handles default column width greater then 32 characters properly.
  • Script function call() also execute binaries which are located in the sytem search path.
  • Fixed issue if a measurement list filter using database groups is modified.
  • The script function SetCurrentDevice() can be used to remove definiton of the current device.
  • Fixed issue if more than expected files are selected for a measurement file export converter.
  • Fixed issue if the application is started using a 8.3 DOS file name.
  • Resizing of display windows is possible even the window is maximized on another display page.
  • Rename and fix of script function DiagExcecuteJob() into DiagExecuteJob().
  • Fixed issue during initialization of dynamic managed main menu entries.
  • Display the raw value of signals in graphic windows even the raw value is mapped to a status table entry.
  • Fixed issue which may have truncated the project file if the same project was reloaded after close.
  • New switch to display the legend of the numeric array display window which is hided by default.
  • Skripts added to the task manager are not recompiled at start if only the current device has changed.
  • Fixed issue in case of changing the font in the function browser settings.
  • Parameter and signals of the current configuration without a database description are marked with a specific icon, e.g. to identify them in the search result of the Symbol Explorer.
  • Performance improvements (Open DeviceExplorer window).

Communication Protocols:

  • Fixed issue which prohibited creation of analog devices.
  • Fixed timestamp issue when using CAN channels from VX1121.
  • Fixed CANextender device configuration issue.
  • FlexRay: Improved handling of null frames in the static segment.

Measurement Data Acquisition:

  • Changed logical channels are stored accurate in the next measurement files.
  • The detection of low memory in case of storing many measurement data in the display buffers works on systems with more then 4 GB.
  • Fixed issue in case of measuring an empty string.
  • Fixed issue with splitted MDF3 measurement files with more then 256 data groups during measurement.

Offline Analysis of Measurement Files:

  • Support of conversion rules for MDF objects as input for MATLAB/Simulink objects and functions.
  • MDF merge converter handle files if first measurement value time stamp is zero.
  • MDF merge/split converter handle MDF files using a offset for time channels.
  • MDF merge converter merge files with different sample reduction blocks (sample reduction is removed).
  • The MATLAB export converter provide measurement files containing structures.
  • Fixed some issues during printing of signal names and indexes.
  • Printer selection on Windows Vista and Windows 7.

Database:

  • Fixed issue with LIN databases containing sporadic frames and no event triggered frames.
  • Bus monitor databases are not marked as modified if the properties dialog of groups is closed with OK.

Automation:

  • Fixed function DBObjectClass.get_Item(SignalName)
  • Fixed macro based MDF file name generation.
  • Increased maximum length of string parameter for function Asap3DiagSetStringParameter.

Diagnostics:

  • Fixed "Tester Present" issue for functional devices.
  • Accelerated flashing.

Data Mining:

  • Boolean expressions using edge functions are never trigger at the first value.
  • Fixed issue if Data Mining Explorer is closed and a deleted analysis is restored.
  • The extension .DMR is added to Data Mining result files even the file name template contains another extension.
  • The calculated values of virtual file signals can be accessed by scripts.