Versionshistorie

2010-11-10: CANdito 5.0 SP2

Download: bitte laden Sie den aktuelleren SP5 herunter. Falls Sie eine Vorgängerversion benötigen, hilft Ihnen gern unser Support-Team weiter.



Die folgenden Änderungen werden mit Service Pack 2 wirksam (SP1 ist enthalten):

User Operation and Display:

  • Do not prevent start of measurement by script by undocked MDI window.
  • The Function Browser shows tooltips for its toolbar icons.
  • The previously selected Label list will be preselected when opening the Measurement Configuration again.
  • New script function RecorderGetFileSize() to get the size of the currently written measurement file.
  • The comment of function definitions is shown both in the tooltip and in the comment column of measurement functions.
  • Restrict number of (trigger) events displayed from MDF4 files to 1000.
  • A minimized Function Browser will be restored correctly after reloading the project.
  • Functions from a DLL are listed in an own submenu of the Function Browser popup menu.
  • Disallow adding signals to a protected Data window.
  • Fixed sort icon in column header of numeric columns in Measurement Configuration.
  • Sub-windows of a Graphic window are shown without title if the option to hide title bars is activated.
  • Prevent update of Parameters by the measurement if they are currently modified by the user or by scripts.
  • Prevent infinite calculation of virtual signals in the background if they have no values due to missing input signals.
  • Global variables of type string now can be assigned to array parameters of measurement functions.
  • Support of Drag&Drop of signals between floating display windows.
  • Function definitions of virtual signals or measurement functions can be viewed even they are not part of the project.
  • Improved device status display.

Communication Protocols:

  • Fixed GPS configuration issue.
  • KWP: Fixed issue which disallowed script execution and starting the measurement.

Measurement Data Acquisition:

  • The maximum size of comments entered during measurement is 8000 characters.
  • Keep complete history of calibration comment and write window signals when cutting trigger time range in case of saving individual measurement file for each trigger.
  • Optimization of measurement buffer memory management to support triggered measurements with high data rate.
  • The measurement signal list is exported with measurement mode into CFG files. During import these measurement modes are used.

Offline Analysis of Measurement Files:

  • The CallConverter command line tool supports a list of file names/names with wildcards to process several files.
  • The comment of MDF files can be displayed in the Preview Pane of file open dialogs or the Windows Explorer.
  • The address and Linker Map reference of ECU variables can be added to the channel description in MDF4 measurement files.
  • Allow loading MDF4 measurement files containing cuboids (will be ignored, display of cuboids is not supported yet)
  • The Measurement File Manager remembers the size of its columns.
  • The logging import converter supports Flexray frames transmitted in multiple slots.
  • Axis values of maps and curves from measurement files will be displayed even they are stored only as raw values or if the map is not quadratic.
  • The ASCII Import converter supports time columns containing time stamps in US American date format and measurements beyond midnight.
  • The display configuration is added to signals from MDF4 files if they are saved in a new MDF4 file.
  • The MATLAB export converter for measurement files supports the option to start at time 0s.
  • In case of displaying signals from MDF3.2 files with absolute time, the local time of the time zone during recording is used.

Database:

  • New script functions FileFindFirst(), FileFindNext() and FileFindClose() to support searching for files in file system.

Automation:

  • New script functions CreateUUID(), UUIDToString() and StringToUUID() to support creation of measurement or parameter files containing a UUID.
  • Fixed recorder state information.
  • The interpolate function of the scripting language is extended to support maps.

Diagnostics:

  • Scripts generated by Diagnostic Console are added to the opened Function Browser.
  • Improvements for Variant Coding Window.
  • DoFR: Improved device configuration with regard to request and response PDU.
  • Unified ODB device configuration GUI.
  • DoFR: Fixed communication issue in case of FlexRay frames having update bits.
  • DoFR: Improved stability of communication.

Data Mining:

  • Added possibility to create new scripts in the configuration dialog of Data Mining scripts.