2009-03-10: CANape 7.0 SP3

Download

Die folgenden Änderungen werden mit Service Pack 3 (Update auf 7.0 Build 30, SP1 und SP2 sind enthalten) wirksam:

General Usage:
  • Project Management: Use dereferenced link instead of the link itself.
  • The selection of tabs of some dialogs does work on a secondary monitor left of the main monitor (negative pixel coordinates).
  • The name of devices created from a database file can be modified now.
  • All selected elements of an array are inserted as block into a display window.
  • The configuration of signals stimulated by functions is not lost if the device is offline during saving the configuration file.
  • Limit of MDI windows is increased in case of more system resources.
  • The selection of a logging file for the trace window does not change the working directory.
  • The order of parameters in a parameter window is saved correct to the configuration file.
  • Partial loading of calibration objects from configuration files does work now.
  • The file selection control of Panel windows show the predefined file name.
  • Add checksum type CRC16_CCITT and custom_dll to hex-window supported checksums.
  • Fix compatibility issue for CRC16_CCITT.
  • PDB map file reader supports arrays of structures of all data types now.
  • Improved Visual Basic diagnostic example for Vista compatibility.
  • Add support of Fixaxis descriptions with floating point numbers.
  • Numeric curve Window : Save the list of parameters in the correct order.
  • Correct handling of master database if the global filter (label list) is activated.
  • Calibration window map/curve graphic: Checking the readonly state of a parameter and disable the edit fields.
Measurement (expanded measurement data acquisition):
  • Fix of a problem in case of opening the structure tree the first time during measurement.
  • Update display elements of arrays even only one element is displayed.
  • Fix some problems for signal filters in the measurement configuration.
  • Components of sub structures can be assigned to ActiveX elements.
  • Axis measurement objects are removed from the measurement list if their array is removed.
  • Measurement signals are displayed in the graphic window even they are activated after measurement was started.
Communication Protocol:
  • XCP on Flexray: Export all conversion rules to the logging configuration file.
  • CCP: Export CALRAM segment property "READONLY" to A2L file.
  • CAN: Fix issue which lead to missing signals at trace window.
  • Fix XCPonUDP communication configuration error.
  • Improve memory upload progress bar status.
  • XCP userdefined driver: fix communication issue.
  • Add error event which signals the occurrence of ECU DAQ buffer overrun.
  • Fix time drift issue for FlexCard II.
  • CCP/XCP: Fixed rounding issue for cyclic measurement mode.
  • Removed wrong error message while creation of K-Line driver.
Functions and Scripts:
  • Components of sub structures can be assigned to function parameters.
  • The internal function GetLastEvent() returns the event code of the triggering event even another event occure before execution of the function.
  • Fix of a problem in case of a wrong format string for the internal function SystemTime().
Offline Analysis:
  • CANconv Import Converter supports CLF logging files from GL1000 data loggers.
  • MATLAB export converter does export all signals even the option to use display names is activated.
  • File extension of exported MATLAB files is in lower case now to be useable on Unix based systems.
  • The ASCII import converter of measurement data supports absolute time stamps.
Automation:
  • Reading specific A2L files for MCD 3MC server use case improved.
Database:
  • The Interface Data Blop "CANAPE_EXT" of A2L files is written compatible to old CANape versions.
  • A problem is fixed that may result in wrong names of structures of the structure tree.
  • Fix of a problem during the A2L plausibility check.
Data Management (optimized calibration data management / CDM Studio):
  • Concatenate calibration ram segment before calculate the parameter list. As result parameters which overlapped between two segments ar included in the result set.
  • CDM-Studio: Add support of shared axis which refer a record layout with dynamic axis points.
  • CDM-Studio Check column descritpion against the PAR file specification to prevent not well formed file creation.
  • Disable menu command "Save parameter set in binary format" when CANape runs as diagnostic tester.
  • Display a message box if no variant is available if the user will change the variant and no variant description is available.
MATLAB/Simulink Support:
  • Improved ASAP2 generation and CANape Model Explorer. Please see CANape RT-Target readme for details.
  • Simplified installation of MATLAB-API package.
Advanced Multimedia:
  • Only the first video device capture output pin is used for capture and preview.