Versionshistorie

2007-10-12: CANape 6.5 SP1

Download

With Service Pack 1, the following changes become effective:

General:
  • GUI harmonisation for CANditoFlash
  • Improved CPU load distribution on multiprocessor systems
  • The former "Advanced Multimedia" feature "Shift multimedia signal for offline evaluation" is always available now
  • Visibility of the undocked symbol explorer is assured
  • Axis scaling keeps unchanged when signals are moved from one display window to another
  • Fixed partial loading of windows which were displayed on multiple pages
  • Fixed problem in non modal ASAP3 mode (query message for "Save Configuration" on exit)
  • Fixed problem with Macros for Text To Speech
  • Fixed Problem with curve windows and more than 10 curves
Measurement:
  • Saving a measurement label list is possible even if no device is selected
  • Curves with one column and multiple rows are now always handled like array signals
  • The logging file of the write window is completely written when measurement stops
  • Fixed issue regarding default measurement modes listed in measurement list
Calibration:
  • Indirect modified parameters that are in the measurement list, are not updated until their new value is downloaded to the ECU
  • KWP2000 on K-line: KW_Standard.dll now supports parameter calibration while measurement is running
Flash Programming:
  • Use seed&key dll when flashing via CCPflash.exe
  • Possibility to reduce STmin to speedup flashing
  • CCP/XCP: Unlock required protocol resources for flashing
Database Editor:
  • Sort order of the database explorer lists are saved individualy for each object type
Functions and Scripts:
  • Path of a script added to the Extras menu can be relative now
  • Measurement file signals can be directly accessed by functions to create virtual MDF signals
  • Usability of the function browser "Intellisense" improved
Communication Protocols:
  • Handle french keywords for memory segments in ASAP2 file
  • Fixed problem reading FIBEX databases which contains CAN clusters
  • Full support of J1939 for CANalyzer/CANoe ASC logging files
  • Support of CAN DBC databases with multiple multiplexer signals
  • Support of all LIN message types of CANalyzer/CANoe BLF logging files
  • XCP: Support STIM only bypassing
  • Improved FlexRay error messages
  • Fixed stability problem when using the BusDoctor as FlexRay interface
  • Fixed timestamp problem which occurred after resynchronisation of the FlexRay interface
  • Fixed issue when importing A2L database which resulted in corrupt flash offsets
  • XCP on FlexRay: fixed problem when deleting a FlexRay device
  • XCP/CCP increased limit for LOAD_GRANULARITY to 65535
  • XCP/CCP added trace coloring for CMD and RES packets
MATLAB/Simulink Support:
  • Improved MATLAB/SIMULINK support for generated A2L files
  • Project "save as..." does also store the MATLAB/Simulink model graphics
  • Include the comment in the saved file when using MATLAB as target format
  • Option to save maps in column direction when using in MATLAB format
  • Fixed problem when creating a XCP module via the Matlab API
Data Management:
  • Improved handling of variant coded parameters of the current device (C&P, save as...)
  • Support sorting of items in CDM-Studio based on their address
  • Added a new option to define a user defined filter: Filter the variant information only if the current group is variant codded
  • Store display and sort configuration for the current device separate from the other settings
  • Improvements in reading DCM and CVX file which contains parameters using a symbolic conversion table
  • Restore the column order a reloaded parameter set file if the CDM-Studio is reopened.
  • New menu item to adjust the column size of all opened parameter set files
  • Support longer file names in the file open dialog of CDM-Studio.
  • Restore the "All parameter set files" also as predefined filter in the open file dialog of CDM-Studio.
  • Improvement in loading variant coded maps with standard axis
  • Export filter contents with the current sort order from the GUI
  • Improvement in handling parameters with overlapping addresses in the save action
Offline analysis measurement files:
  • Improved signal selection from measurement files.
  • A start time can be specified for importing ASCII measurement files.
  • A time unit (factor) can be specified for importing ASCII measurement files.
  • Command line option -M opens a measurement file without a signal selection dialog
  • The comment in Diadem export files is checked for unsupported characters.
  • The first Application Text Object in an CANalyzer/CANoe BLF logging file is used as comment for the MDF file.
  • Measurement files loaded inside the measurement file manager are loaded permanently.
  • Display FlexRay signals from CANalyzer/CANoe logging files.
Diagnostic:
  • Fixed problem in CANape scripting regarding diagnostic response handles in case of mixed physical/functional addressing usage
  • Fixed problem with CANape scripting command DiagSendRequest() in case of raw messages if no diagnostic database is used
  • Performance improvement building the service tree of the diagnostic console window
  • Fixed problems regarding bit field handling of CANdela service parameters
Map Reader:
  • ELF mapfile reader supports bit structures correct now.