Home  > Company  > News  > Service Packs  > Archives
 

News

2010-01-15: CANdito 4.0 SP2

Download

With Service Pack 2, the following changes become effective (SP1 is contained):

New Features:

  • Support of the operating system Windows 7 32 Bit.
  • Kvaser Memorator logging files (.kme files) can be imported.
  • Improved Data Mining functionality (see online help).
  • Usability of the .NET Panel ActiveX is improved.
  • New ASCII export converter option: The comment of measurement signals can be used as signal name.
  • The Matlab export converter can export a subset of signals.
  • Open only one instance of the .NET Panel Designer for the same panel.
  • Hex file functions can be used in scripts during measurements.
  • New global option to disable drawing of the trigger events in graphic windows.
  • Improved display of the envelope curve for all zoom factors.
  • CANditoAPI: New functions for resume mode measurement and time sync management.
  • Toolbar button added to toggle an ECU device between calibration RAM and Flash.
  • Improved support of different file extionsions related to MOTOROLA-S format.
  • New switches (CANDELA_STMIN_HANDLING_OFFSET, CANDELA_TRANSFER_ACCELERATION) for faster flash programming.

Improved user operation and display:

  • Enhanced Project Management for data mining files.
  • Increased number of files which can be zipped using the Project Management feature.
  • Usability of the .NET Panel ActiveX is improved.
  • Drawing of the envelope curve for white display window background.
  • Drawing problems concerning printing of display windows fixed.
  • The column settings of graphic windows are saved for every component window.
  • Issue with deleting virtual signals or functions, which are displayed by a data window, solved.
  • Issue fixed if an object is deleted and a setup dialog of a display window is open which contains the deleted object.
  • Assignment issue of Graphic window displays to common axis fixed.
  • The correct background color is used if the envelope curve is displayed if some signals are disabled.
  • The width of the columns in the display window legend can be changed if the header line is invisible.
  • After loading a second configuration the global cursor is set to the correct time.
  • Fixed issue concerning the execution of scripts calling subfunctions which return with cancel via panel buttons.
  • Fix of an issue concerning the creation of a project folder on a Japanese Windows Vista.
  • Saving the Function Browsers local setings on a system using UAC.
  • Signals can be enabled and disabled in the graphic window settings dialog. Signals used as X axis are enabled automatically.

Extended measurement data acquisition:

  • Flush mode used by the Server during saving measurement files can be defined in the project file.
  • Fixed issue with measurement data storage in memory on some computers with multiple cores.
  • Option "Do not measure polled signals if display windows are minimized or invisible" supported for measured calibration parameters.

Communication protocol:

  • Tracing logged messages: Functionality improved.
  • CAN Monitor: Fixed asynchronous start.

Offline analysis of measurement files:

  • Fixed error message in case of envelope curve calculation for virtual Matlab signals with multiple function results.
  • Solved redraw problem of multiple graphic windows on some computers with multiple cores.
  • Array signal elements from measurement files can be used for X/Y displays.
  • Converter setting "overwrite existing target = false" is accepted if the converter is started for the second time by a script.
  • Support of interpolation of signal values by the MATLAB and the ASCII export converter.
  • Fixed error message in case of envelope curve calculation for imported measurement files.
  • Default settings of the ASCII export converter are changed in case of an english version.
  • Logging import converter does not create MDF files bigger than 4 GB.
  • Trigger events are also saved if signals from a graphic window are saved in an MDF file.
  • Sample Reduction is supported for measurement files with virtual time channels.
  • The Vector logging import converter supports time stamps and time syncronisation for CCP/XCP DAQ messages.
  • Persistent assignment of virtual MDF signal input parameters to parameters if a calibration window containing these parameters is closed.
  • Temporary files created for unsorted and write protected measurement files are deleted.

MATLAB/Simulink support:

  • Create valid global variable names during auto linkage of MATLAB/Simulink DLL inputs/outputs.

Diagnostics:

  • CANditoFlash: File path of Vector Flash Container may contain spaces.
  • Improved handling of periodical transmission of functional addressed TesterPresent requests.
  • Fault Memory: problems displaying text in Chinese OS windows fixed.
  • The base variant is used as default variant for all means of creating a new device.
  • Online state in diagnostic console, fault memory, and OBD window is updated consistently.
  • Trace window displays services executed for variant identification.
  • CANditoFlash: fixed issue with closing the application while a flash procedure is still running.
  • Fixed issue with invalid value ranges of block size and STmin parameters.
  • CANditoFlash: fixed issue with Start Flash Download button.

Automation:

  • CANditoAPI: CAN device function "Asap3CreateModule" was improved to avoid assignment problems.
  • CANditoAPI: Support of ENVIRONMENT device.

 

[more about CANdito...]

[back]

Print this page | Imprint | Add page to favorites

© 2006-2010 Vector Group