With Service Pack 2, the following changes become effective:

New features:
  • Display names of module perspectives in project explorer
  • Usage of license.bin becomes obsolete
  • Support PreConfigured and Recommended Class Configuration
  • The display format of Integer parameters can be changed by user to decimal, hex or binary format
  • Support GENy dll for generation of SWC
  • Full integration of new Project Assistant in user interface
    • Create new EcuC project based on system extract
    • Update current EcucC project with new modified system extract
    • Edit common project settings
  • Establish context menu for each parameter to support actions to
    • add or modify a comment string
    • reset the parameter value to the specified default value
    • reset the parameter value to the specified recommended value
    • open a pop-up window with all information raised from definition
  • Support AUTOSAR release 3.1 (together with accrued patch releases 3.0.3, 3.0.4, 3.1.1, 3.1.2)
  • Support usage of identifier.xml to cover extensions of AUTOSAR specification
  • Support derived parameter types with Vector formula description
  • Support concurrent Ecuc access between MICROSAR tools
  • Enhanced performance when opening and changing module views
MICROSAR Generator:
  • Restrict loading to necessary dependent BSW modules to enhance performance
Fixed issues:
  • Missing external generator will not be reported
  • Error message for external generator is not ok if its path contains blanks
  • Renaming SymbolicNameRef parameter results in invalid value
  • If an existing but invalid PackageLicense entry is found in any project, the project will not be loaded
  • Save module configuration to Ecuc only if really changed
  • Deactivating modules does not work in some cases
  • Parsing definition files fails sometimes if additional files found e.g. /bswmd/project.pj
  • Ecuc change detection hangup in a special environment
  • The mouse pointer will not be set back to default on leaving project explorer
  • Relative paths are resolved not relative to project folder
  • Import Append fails sometimes
  • Context menu item 'JumpTo' becomes not enabled
  • Calling external generator removes foreign created temp files
  • ProjectAssistant - ask user if configuration shall be saved before 'update ecuc project...' is executed
  • General values of ecuc file will not be loaded if contained modules are not known in PackageLicense
  • Ecuc-File change detection shall not be executed when DaVinci Configurator is not focused
  • Relative specified DaVinci ProjectAssistant projects are not generated into correct folder
  • Correct support of underscores in module and parameter names in parameter definition file
 