News
2012-01-17: DaVinci Developer 3.0.33 SP1
Download
With Service Pack 1 (Update to 3.0 Build 33), the following changes become effective:
Tool features:
- Support of LIN Signal-Groups defined LDF files with the naming convention <signal_group_name>__<signal_name>.
- AliveTimeOut is now imported from DBC and can be propagated using a new function in the data mapping view.
- The newly introduced automatic ECU-C synchronization during workspace load/save can be switched off in the global settings dialog.
- Display of calibration objects in the graphic can be switched off in the workspace settings.
- Support of ARXML import pre-configuration using generic attribute IMPORT_MODE_PRESET.
- Constant property "Generate Symbol" can now be set in Library-Browser via multi-selection.
Fixed issues:
- Wrong workspace conversion that causes missing Signal Group references during ECU-C synchronization has been fixed.
- Inconsistent connections (wrong sender/receiver direction) were not detected by a consistency check.
- Error message in the GUI when changing R-Port's "Handle Invalid" property has been fixed.
- Compatibility settings could not be set properly in the workspace settings dialog.
- DCF Utility did not show Activation Offsets in the ECU-Project binary file.
- Missing check messages on inconsistent data mappings have been added.
- Additional name information for "DEFINITION-REF" objects in difference view have been added.
- Inconsistent structure of a complex constant compared to its data type have caused a generation error even if the constant was not actually generated.
- Out-of-memory error message occurred in DCF Utility when opening large dcb files.
- Missing sorting of FIBEX-ELEMENT-REF in difference view has been fixed.
- Crash in DaVinci DEV has been fixed when switching to the ModeDelarationGroups in the properties view.
- Show in software design command for runnables in task mapping page did not work.
- Error Handling for ModeQueueLength '0' has been corrected.
- Within the data element prototype page the CreateNewDataType button did not work.
- During ARXML import the renaming a child object did not always work if the names only differ in character case.
- External tool command line parameters are changed back to default if no parameters are given in the dialog.
- The consistency check for Calibration Ports has been weaken to allow compatible interfaces that are not identical.
- ARXML import failed if existing objects only differ in character case from objects that were to be imported.
- Tool crashed when saving new SwBlockNeeds with a mirror PIM that had no data type.
- In read-only SWCs the implementation popup menus were not disabled and tool crashes if menu commands was executed.
- Tool slowed down after running several hours because of GUI resource leaks.
- Wrong setting of working folder in attached files dialog fixed that caused error message while opening generated attached SWC template file.
- Generated OSAlarm and OSEvents did not match because the setting 'use shortnames > 32' was not consistently communicated to the RTE.
- Added multiple mapping of the same system signal on one frame to support the multiplexing use-case.
- Extended support for Tx/Rx split and signal overlay in the Multiple-ECU use-case.
- ARXML runnable import of Init-Trigger corrected if no other Trigger exists.
- Fixed error while synchronize structure of a complex constant in AUTOSAR export if the structure of the complex data type has been changed.
- Newly created graphic sheet names were not stored correctly in the workspace.
- ECU-C file data was not fully loaded during opening DCF workspace if the AUTOSAR schema versions have been different.
- Generic attribute definitions were not loaded during opening DCF workspace if a corresponding generic attribute did not exists at an AUTOSAR object.
- Missing error message while opening incompatible workspace with RTE Generator fixed.
- Generation of templates and contract headers is now allowed for service components.
- Sorting of error/warning/info icons in the messages tab has been corrected.
- The initial graphic scroll-bar position was often not correct.
- Newly created Port-Prototypes are now automatically positioned near the original port.
- Auto-mapping for was not working well with multi instance SWC.
- Directory placeholders with workspace variables were not working correctly for DCF workspaces.
- Service mapping was missing when exporting service layer components to ARXML or DCF.
- Property dialog for NvM block needs threw an error when using read-only Component-Types.
- Some issues in workspace merger functionality have been fixed concerning communication merge, generic attributes, and data-mapping.
- The global attribute definition file in a DCF workspace can now be modified in the DCF-file to share it among DCF workspaces.
- The Mode disabling dependencies for runnable triggers were doubled during the XML import.
- Task attributes priority / description / schedule were incorrectly loaded from DCF workspaces.
- Signal bit length was not updated from DBC file if the signal with data-type reverence already exists.
- Service needs were deleted during special diagnostic import.
- Bad performance while switching from structure design to port prototype view solved by specifiying the livst view as default editor for non-graphic use-cases.
- ECU-C sychronize of Init Values produced unnecessary warning output.
- Init value check for the Data Mapping did not work.
- Incorrect Exclusive Area Access after DCF loading if AR 2.1 SWC are used together with AR 3.0 ECU-C file.
- Attribute definition inconsistencies were not reported during DCF loading.
- Inconsistent NvM block and PDAV order was not reported by a check.
- Signal's unit was not imported via LDF file.
- Crash has been fixed while opening ECU Project Software Design editor after large SWC was updated by importing new SWC definition.
- Loading of global generic attribute definitions has been restructured to avoid overwriting with local attribute definition during DCF loading.
- Wrong consistency message concerning maximum values was displayed due to rounding problems in physical value calculation.
- Workspace settings were reset on saving a DCF workspace as DEV.
- Read-only ECU-Projects were missing after loading a DEV workspace which was created out of an DCF workspace.
- Crash during DCF save has been fixed if many read-only DCF files are about to be stored.
- Signal length was set to null after a LDF file has been updated through the ECU-Project signal list.
- Data mapping was missing after loading DCF workspace if atomic software components were multiply instantiated within an ECU-Project.
- Update icon was not correctly displayed in Attached-Files dialog
more about DaVinci Developer...
Did you find this page helpful?