Download
With Service Pack 2, the following changes become effective (SP1 is included):
General Usage:
- Symbol Explorer: "Search result" can be sorted by column "type"
- The name of the current loaded configuration is not changed if loading of a invalid configuration file was denied
- The sort order of inserted signals in display windows is top down again
- Symbol Explorer: The context menu does work on a secondary monitor with negative pixel position
- No range info tooltip displayed for string parameters any more
- MCD-3D: Fixed problem of project selection that occured when cancelling the MCD-3D device creation
- Improved T-Systems MCD3 server integration (apply system settings on server startup)
- Setup: Users having no administration rights are able now to modifiy the assignement of logical hardware channels
Measurement ( Expanded measurement data acquisition )
- Support of an external time master. The time master can be activated in the device configuration
- System event "Measurement Start" can be used to start a triggered recorder
- CCP and XCP error events can be used to trigger a recorder.
- An error message is reported to the write window if automatic start of measurement is not possible because missing Licence
- Recorder is stopped after sum of maximal stop time and post trigger time if the stop event does not occur
- Measurement functions executed "On Key" do not break the measurement if they show a dialog
- The type of conversion rules can be displayed in the GUI (Column "Type of Conversion")
- Virtual database signals or measurement functions are inserted with a valid default measurement mode
Communication Protocol
- J1939 filter settings of CAN devices can be defined individual for each device now
Functions and Scripts
- A UserQueryDialog opened by a script is suppressed if the application is started in silent mode (Commandline option -q)
- Fixed problems when changing tester present state form scripts
MATLAB/Simulink Support
- Multiple selection can be used during assigning signals to parameters of a MATLAB model.
Offline Analysis
- Support visualisation of GIN Multilog data files (CLF files)
- Partial loading of virtual signals does not duplicate the parameter list for each display of the signal.
- ECU signals measured by XCP on FlexRay are created in the same way by the BLF import converter as by CANape during measurement
- The time grid values created by the ASCII Export for measurement files are rounded depending on the grid raster
- When importing CAN logging files, CAN remote frames are not imported by default (added option to enable this feature)
- Display structure component values after load of measurement files
Diagnostic ( More extensive diagnostic options )
- OBD and Variant Coding diagnostic windows can be exported as bitmap now.
- New context menu "Create OBD Report..." available in OBD Window
- The OBD window now handles freeze frame scans for ECUs that do not send a response for a unsupported frame number
- OBD: Fixed problem with extended (29 bit) CAN IDs for functional request messages ($18DB33F1)
- OBD: Added progress bar display while performing the OBD network scan
- New "Create report…" function to export the OBD data to an XML file
- Improved performance of diagnostic console service tree display
CANditoFlash (More flexibilty)
- Communication parameters can be optionally imported from ODX or CDD file
- No separat tool needed any longer to create a flash container
- Edit the configuration file that controls/parameterizes the flash script, insert the configuration file to the flash container

Kontakt