News

2009-01-05: CANdito 3.0 SP2

Download

With Service Pack 2, the following changes become effective (SP1 is included):

General Usage:

  • Symbol Explorer: "Search result" can be sorted by column "type"
  • The name of the current loaded configuration is not changed if loading of a invalid configuration file was denied
  • The sort order of inserted signals in display windows is top down again
  • Symbol Explorer: The context menu does work on a secondary monitor with negative pixel position
  • No range info tooltip displayed for string parameters any more
  • MCD-3D: Fixed problem of project selection that occured when cancelling the MCD-3D device creation
  • Improved T-Systems MCD3 server integration (apply system settings on server startup)
  • Setup: Users having no administration rights are able now to modifiy the assignement of logical hardware channels

Measurement ( Expanded measurement data acquisition )

  • Support of an external time master. The time master can be activated in the device configuration
  • System event "Measurement Start" can be used to start a triggered recorder
  • CCP and XCP error events can be used to trigger a recorder.
  • An error message is reported to the write window if automatic start of measurement is not possible because missing Licence
  • Recorder is stopped after sum of maximal stop time and post trigger time if the stop event does not occur
  • Measurement functions executed "On Key" do not break the measurement if they show a dialog
  • The type of conversion rules can be displayed in the GUI (Column "Type of Conversion")
  • Virtual database signals or measurement functions are inserted with a valid default measurement mode

Communication Protocol

  • J1939 filter settings of CAN devices can be defined individual for each device now

Functions and Scripts

  • A UserQueryDialog opened by a script is suppressed if the application is started in silent mode (Commandline option -q)
  • Fixed problems when changing tester present state form scripts

MATLAB/Simulink Support

  • Multiple selection can be used during assigning signals to parameters of a MATLAB model.

Offline Analysis

  • Support visualisation of GIN Multilog data files (CLF files)
  • Partial loading of virtual signals does not duplicate the parameter list for each display of the signal.
  • ECU signals measured by XCP on FlexRay are created in the same way by the BLF import converter as by CANape during measurement
  • The time grid values created by the ASCII Export for measurement files are rounded depending on the grid raster
  • When importing CAN logging files, CAN remote frames are not imported by default (added option to enable this feature)
  • Display structure component values after load of measurement files

Diagnostic ( More extensive diagnostic options )

  • OBD and Variant Coding diagnostic windows can be exported as bitmap now.
  • New context menu "Create OBD Report..." available in OBD Window
  • The OBD window now handles freeze frame scans for ECUs that do not send a response for a unsupported frame number
  • OBD: Fixed problem with extended (29 bit) CAN IDs for functional request messages ($18DB33F1)
  • OBD: Added progress bar display while performing the OBD network scan
  • New "Create report…" function to export the OBD data to an XML file
  • Improved performance of diagnostic console service tree display

CANditoFlash (More flexibilty)

  • Communication parameters can be optionally imported from ODX or CDD file
  • No separat tool needed any longer to create a flash container
  • Edit the configuration file that controls/parameterizes the flash script, insert the configuration file to the flash container