News
2008-02-26: CANape 6.5 SP3
DownloadDie folgenden Änderungen werden mit
Service Pack 3 (Update auf 6.5 Build 30) wirksam,
SP1 und SP2 sind enthalten:
General:
- Unknown window types of configurations from higher application versions are ignored now. The configuration is read without an error.
- Problem fixed in case of moving the global cursor in pause mode during measurement.
- Database editor can be closed even there is a invalid curve dimension.
- Problem fixed if moving an icon of the toolbar is cancelled with ESC.
- Fix permanent redraw of the measurement configuration dialog if this dialog is placed on a second monitor left of the main monitor.
- The file name of a CAN device logging file can be extended by the device name to get unique names.
- Performance of the measurement configuration dialog for very large configurations improved.
- There is a warning message if a project or a configuration from a higher application version is loaded.
- Signals from measurement files can be displayed during measurement.
- Issue with measurement configuration dialog fixed.
- Fixed issue when loading an A2L file having more than 64 memory segments.
- Problem fixed of the ELF map file reader in case of more then 16000 source files.
- Problem fixed of the ELF map file reader in case of bit field members crossing byte borders.
Function and Scripts:
- Only save a description of the referenced global variables into the configuration.
Communication Protocols:
- CAN Remote frames are logged as remote frames into the CAN device logging file.
- Improved Tracing of XCPonFlexRay messages (cycle, channel and XCP-NAX).
- Decrease Reconnect delay in Datalogger mode (when restarting measurement).
- Fixed issue when measuring multiplexed FlexRay signals.
- Fixed issue when measuring FlexRay signals having multiple conversion rules.
- Improved XCPonFlexRay dynamic bandwidth distribution.
- Support FlexRay bus logging to file (BLF).
- Support VX11xx CAN channels for CAN monitoring.
- Added XCP specific driver setting to suppress automatic reading of XCP event definitions.
- Fixed issues related to XCP static DAQ lists.
- Improved error handling when unplugging ethernet cable of active XCP connection.
- Added warning in case of duplicate or missing XCP DAQ data.
- Fixed timestamp issue when running long XCP measurements > 12 h.
- Support VN7600 interface hardware.
- Fixed data loss issue for ethernet based XCP on multicore computers.
- Fixed connect abort which occurred in case of error frames on CAN bus.
- Improved error report in case of inconsistent FlexRay database configuration.
- Generate Datalogger Configuration for XCP on FlexRay (not available for concatenation mode).
- Fixed issue which lead to mixed XCP measurement data in case of STIM or static daq lists.
- Fixed issue related to test of measurement configuration in case of XCP on FlexRay.
- Improved device creation of XCP on FlexRay devices.
- Fixed issue which prevented XCP stimulation on PDU based FlexRay networks.
- Fixed configuration issue affecting logical FlexRay channel setting.
- Fixed issue which lead to inconsistent measurement data in case of FlexRay networks.
- Fixed instability issue related to user defined XCP dlls.
MATLAB/Simulink Support:
- Tooltip support in the MATLAB Model Explorer hierarchical view and search result.
- Always all STIM events of a device are available.
Multimedia:
- DivX 6.8 support by setting a registry key during the installation to ignore the DivX setting 'use hardware overlay'.
- On adding a multimedia measurement object to the multimedia window it displays the video immediately if the option "Display values from measurement file…" is set.
Data Management:
- Correction in calculating the equal state if vlaues of the current device are involved.
- Improve load parameter set files for virtual parameters.
- Fixed issue if parameter based on datatype FLOAT is stored in PAR format.
- Expand the pathname with the correct directory if the filname is not complete during the save parameter set action.
- Correction in Checksum algorithm ADD_DWORD_DWORD.
- Display correct axis value in parameter explorer window.
- Improve detection of format errors in DCM files in case of parsing of double values.
- In CDF20 files do not write axis points of common axis / rescale axis or curve axis with their curves and maps itself.
Offline Analysis Measurement Files:
- Merging of unsorted and write protected MDF files is possible now.
- Merging of MDF files is possible too if the source MDF files have records with and without record identifiers.
- Signal value comments of a measurement file are saved if the measurement file is replaced by another file using the command "Display from measurement file".
- The automatic zooming of a graphic after inserting a file signal can be reverted with one click even multiple signals are inserted.
- Import converter for CANcase XL Log logging files optionaly generates a signal for the SyncPulse events.
- Import converter for Logging files support conversion rules from FIBEX databases.
- Import converter for Logging files reports an error if a unsupported file format is selected.
- Fixed problem of the Logging file import converter under Windows Vista.
- The size limit of the label list input field of the ASCII export converter options is removed.
- Problem fixed in case of saving measurement file signals using a measurement configuration.
Diagnostics:
- Diagnostic Console: Checkbox for automatic parameter initialization disabled in case of ODX.
- Diagnostic Console: Improvement of macro recording in case of requests with no response.
- CANape API: Possibility to iterate through complex responses.
- Fixed problems with automatic script creation (macro recording) for parameter value containing special character '%'.
Fanden Sie diese Seite hilfreich?