News
2007-12-03: CANape 6.5 SP2
DownloadDie folgenden Änderungen werden mit
Service Pack 2 (Update auf 6.5 Build 20) wirksam,
SP1 ist enthalten:
General:
- The installation does install a virtual CAN bus if no CAN driver is available on the system. Existing CAN driver < version 5.2.62 is updated
- Optimized update of the Symbol Explorer during import of a database
- Store column witdth for signal name in parameter explorer
- The 'video stream' properties dialog of a multimedia object displays the current values instead of the default values
- Additional panel ActiveX controls are installed
- Even a configuration contains missing parameters, all other parameter values are shown at project startup
Functions and Scripts:
- Problem of the script compiler is fixed if signals with modifiers are used without a device name
Communication Protocols:
- By default measurement of CAN Remoteframes is disabled now
- Fixed CALRAM upload issue when LOAD_GRANULARITY was not a multiple of 4
- Fixed issue with prohibited XCP STIM in conjunction with static DAQ lists
- Fixed XCP issue when MAX_DTO exceeded 255 bytes
MATLAB/Simulink Support:
- The new MATLAB/CANape Integration Package does support MATLAB R2007b and the Microsoft Visual C++ 2005 Express Edition. Furthermore, the exported EMF file names are calculated and also stored in the model description file
Data Management:
- Correction in working with the limit violation option in CDM Studio to support this also if a parameter is modified
- Improvement in numeric detail window to handle the selection correctlly
- Correction in CDF20 reader to support whitespaces
- Correction in writing DCM files. Type ASCII must not include EINHEIT_W
- Correction in working with the limit violation option in CDM Studio to support this also for the current device
- Correction in working with the limit violation option in CDM Studio to support this also for the clipoard
- Correctionin the delete operation to support work with selector objects in CDM Studio
Offline analysis measurement files:
- A text file with signal names can specify the exported signals and the sort order for the ASCII export converter
- ASCII export converter writes the correct hour value in case of absolute time/date
- The index of generated array element signal names in MDF files may have up to 4 leading zeros now
- New main menu command to replace a loaded measurement file
- MATLAB export converter for MDF files with option "Time Grid" starts the time grid at the first signal value now
Diagnostics:
- Support of CANdela(-Studio) Format 5.5
Map Reader:
- Support of ELF map files from Diab Data Compiler V5
Fanden Sie diese Seite hilfreich?