2011-04-18: CANdelaStudio 7.0 SP2
Download
Die folgenden Änderungen werden mit Service Pack 2 wirksam (SP1 ist enthalten):
Issues Solved:
- Corrections to wizard for editing environment data of protocol service 19 06 (EIP11966, EIP20505): if you replace a referenced diagnostic instance by a copy, also copy the involved text tables.
- Preserve modifications in sorted list of wizard for editing environment data of protocol service 19 06 (EIP11966, EIP19992)
- Translation view: avoid error message about translation that already exists (EIP20498)
- Do not delete a DTC when cutting it (EIP18727)
- Corrected search for byte sequences (now detect prefix sequences, EIP20620)
- Preserve more than 6 digits precision in float numbers (EIP21148)
- Avoid unnecessary warnings about CAN Functional Addressing for SingleFrame (EIP19984)
- Excel 2000 not found under Windows 7 for DTC Excel Import (EIP20412)
- Do not allow to break "Required as reference" diagnostic instance authorization by changing activation (EIP21031)
- Avoid issue when changing a data type inside a Mux case (EIP21103)
User Interface:
- Improved compare view (accessibe via "Select as Left Side"/"Compare to", responsiveness, filters, search, navigate to left/right object in document, details window with extra information, multi-selection for upgrade, manual mapping of mismatching template objects, direct comparison of referenced datatypes, differences in languages which are not displayed)
- Improved performance of DTC GUI and import (EIP19572, EIP20030)
- Preserve sort order in datatypes and diagnostic instances list (EIP17003)
- Provide mass change of data types for multi-selected data objects (EIP12236)
- Provide mass change for "Assigned text" and "Additional info" (EIP3718)
- Provide inspection of object properties in telegram table in a packet data type opened from within a diagnostic instance
- Improve inspection of referenced DTCs (EIP20726)
- Convenient creation of ranges for VSG Identifying Patterns (EIP16291)
- Split confirmation settings for insertion and deletion of diagnostic instances (EIP11135)
Other Improvements:
- Export CANdelaStudio version into CDI file (EIP20524)
- Install Effective ODX viewer even if older version already exists (EIP20198)
- Improve the heuristics to locate GraphViz (e.g. under Win7 64Bit, search also in "C:\Program Files (x86)") (EIP20544)
- Show SPN and FMI column (J1939) in DTC list not only for UDS
- Example template UDSonCAN-Example-multilang.cddt: avoid Japanese string for Addressing scheme (EIP20910)
- Do not truncate File dialog (EIP20171)
Data Exchange:
- Ensure COMPARAM-SPEC is contained in exported PDX file (EIP19920)
Customer Specific:
- Do not copy TextID after opening data object property page (EIP21110)
- Warn for duplicate values of DTC attribute "DTC-Error-Name" (EIP17768)
- Correction of CDI file export for FRFM (EIP20563)
- Display default string even without VCK support (EIP20963) Variant coding diagnostic instance