Vector offers you specialized logging solutions for in-vehicle use on test drives or for test benches. Wherever the logging of measurement values from networked systems is required, we provide you with the following data loggers for the bus systems CAN, LIN, FlexRay, MOST and J1708:
[continue to GL1000]
|
-
Comparison of logging solutions
| Technical data |
GL1000 |
GL1010 |
CANcaseXL log |
CANlog 3 |
CANlog 4 |
Multilog |
Bus systems
Logging Interface |
CAN, LIN -- |
CAN, LIN -- |
CAN, LIN, J1708 CAN, LIN, J1708 |
CAN, LIN -- |
CAN, LIN -- |
CAN, LIN, FlexRay, MOST -- |
| Channels |
2 x CAN and 2 x LIN |
2 x CAN and 2 x LIN |
2 x CAN, 2 x LIN 2 x J1708 or combined:CAN/LIN, CAN/J1708, LIN/J1708 |
4 x CAN 1...8 x LIN |
4 +1 x CAN 1...8 x LIN |
8 x CAN 8 x LIN 2 x FlexRay 1 x MOST |
| Memory |
32 GB (on SD/SDHC card) |
32 GB (on SD/SDHC card) |
2 GB (on SD card) |
Internal: 64 MB |
64 MB (on flash card) |
Internal: 100 MB (expandable) 8 GB (on compact flash card, Type 1) |
| Data transfer |
USB |
USB |
USB |
RS232 |
RS232 / USB |
WLAN per IEEE 802.11b/g, USB for external memory media |
Wake-up, Sleep mode functionality |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
| Start-up time |
150 ms |
150 ms |
1 s |
100 ms |
100 ms |
50 ms (CAN, LIN, FlexRay) 1.8 s (MOST) |
Control inputs/ outputs |
2 digital inputs and outputs (0 V...36 V) 4 analog inputs (0 V...16 V) |
2 digital inputs and outputs (0 V...36 V) 4 analog inputs (0 V...16 V) |
1 trigger input |
2 TTL inputs/output, 1 output (V24 level) Optional: Board with choice of digital inputs and outputs or analog inputs |
2 TTL inputs/outputs, 1 TTL output, 1 output (V24 level) Optional: Board with choice of digital inputs and outputs or analog inputs |
8 digital inputs and outputs each Optional: Card with 8 analog inputs |
| Supply voltage |
5.8 V...30 V |
5.8 V...30 V |
7 V...33 V |
5 V...45 V |
5 V...45 V |
5.8 V...32 V (32 V...36 V for elevated power consumption) |
| Temperature range |
-40°...+85 °C (depending on SD card) |
-40°...+80°C (depending on SD card) |
Operating: -20°...+70 °C Storage: -40°...+85 °C |
-40°...+70 °C |
-40°...+70 °C |
CAN/FR: -40°...+70 °C (without WLAN) MOST: -20°..+70 °C (without WLAN) |
| Dimensions (approx.) |
107 x 85 x 35 mm |
130 x 85 x 35 mm |
105 x 85 x 32 mm |
134 × 84 × 35 mm |
140 × 144 × 37 mm |
190 × 240 × 88 mm |
Overview of their highlights:
- Standalone use for challenging logging tasks
- Use in test fleets
- Definition of trigger conditions
- Extensive filtering options
- Flexible configuration using configuration tool
- Offline analysis in CANoe, CANalyzer, CANape and CANgraph
- Customer-specific modifications (hardware, software) are possible
|